2

charger will go into "floating-

charge" stage. The LED indicator will turn to green. The relationship between charging current and charging voltage for each operation

stage are shown in the curves below :

Status Under General Operation:

At the beginning stage of operation, the charger provides the largest current with 13.6Vdc of output voltage (for 12V batteries) to

charge batteries. The LED indicator will lighten in red. After a period of time (probably a couple of hours, based on the capacity of

batteries), the charging current will decrease gradually. After reaching 10% of its maximum value, the

Charging Current and Ambient Temperature

When ambient temperature below 45

, the charging current will carry on the charge by the maximum current surpasses 45

the charge

current will reduce automatically.

Suggested Battery Capacity:

1.It will not have any problem if the capacity of batteries larger than the suggested value.

2.If you have any question about the suitable charging current for the batteries, please refer to the technical data provided by the battery

It just takes more time to make the batteries fully charged!

manufacturers or consult the vendor of the batteries.

Model

PB-230-12

50-160Ah

PB-230-24

24-80Ah

PB-230-48

12-40Ah

Suggested Battery capacity

State

V

boost

14.4V

PB-230-12

28.8V

57.6V

PB-230-24

PB-230-48

V

FLT

13.6V

27.2V

54.4V

Charge Current

stage 1

stage 2

stage 3

Float

Start

Charge Voltage

V

FLT

100%

10%

Red

Constant Current

Constant Voltage

Green

Color of LED

boost

V

L

O

A

D(

%

)

EXTERNAL CASE TEMPERATURE (

)

90

100

80

70

60

40

30

40 45 50