The charger features user selectable 2 or 8 stage charging. The charging profile is selected by moving the slide switch on the back

panel.

7.3 2 or 8 stage Charging mode Select

The charger can be turned ON/OFF by using the "Remote Control" function.

7.Function description

7.1 Remote Control

The charger may be hooked up two battery banks (A and/or B). Connect the battery bank(s) as below. If you are connecting 2

battery banks in the same time, keep in mind that they must share a common ground.

7.2 Two Battery Banks

A

B

1

2

3 4
5 6
7 8
9 10

SW

9

10

CN100

RY13

RY14

RY15

GND

RC-

RY13

RY14

RY15

RTH

RC+

1

2

A

B

8 Stage

+

+

Battery A

Battery B

-

-

2 Stage

Between RC+(pin10)

and RC-(pin9)

SW Open

SW Short

Charger

ON

OFF

Summary of Contents for PB-1000-12

Page 1: ...PB 1000 Instruction Manual...

Page 2: ...UL60950 1 TUV EN60950 1 approved Compliance to EN55022 CISPR22 Compliance to EN61000 3 2 3 Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 light industry level criteria A I P O P 3KVAC I P FG...

Page 3: ...bles between charger and battery should be kept as short as possible to prevent excessive line drop Too much line drop will lead to longer charging period 4 Please make sure charging voltage and curre...

Page 4: ...o Function Description 1 2 3 4 5 6 7 8 9 10 RY13 RY14 RY15 RC RC GND RTH Relay contact rating max 30V 1A resistive Short when the battery A is full Open when the Relay contact rating max 30V 1A resist...

Page 5: ...A Battery B Battery A Battery B Battery A Battery B Battery A Battery B Battery A Battery B Battery A Battery B Battery Soft Start Soft Start Figure 6 2 8 Stage Charging Curve stage 3 stage 4 stage 5...

Page 6: ...is selected by moving the slide switch on the back panel 7 3 2 or 8 stage Charging mode Select The charger can be turned ON OFF by using the Remote Control function 7 Function description 7 1 Remote...

Page 7: ...le wire gauge based on rated charging current Refer to the following table for minimum wire gauge We highly recommend using RED wire for connection and BLACK wire for connection 8 Wiring for battery 7...

Page 8: ...ceed lifespan or damaged Output cables are too thin Ways to Eliminate 9 Suggested battery capacity 1 Batteries in series Voltage can be doubled when 2 batteries are connected in series However the cap...