background image

                             

Installation Manual

 

 

 

 

Type

Enclosed Type Switching Power Supply 

 

(Families: CSP, ENP, G3, G5, HEP, HSP, LRS, MSP, NE, NES, PFC, PSP, PSPA, RS, RSP, 

RST, SE,    SPV, UHP, USP)

 

 

 

Introduction 

Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be 
installed inside the case of the end system. Mean Well’s enclosed type power supplies include 2 different groups of 
power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept. 

 

 

Installation 

1

Before any installation or maintenance work, please disconnect your system from the utility.   

Ensure that it can’t be re-connected inadvertently! 

2

Keep enough insulation distance between mounting screws and internal components of power supplies. Please 

refer to case drawing on specifications to receive the maximum length of mounting screw. 

3

Mounting orientations other than standard orientation or operate under high ambient temperature may 

increase the internal component temperature and will require a de-rating in output current. Please refer to 
the specification sheets to receive the optimum mounting position and information about the de-rating curve. 

4

Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept 

when the adjacent device is a heat source. 

5

Input and Output terminal 

                                                                              Terminal Screw 
Series 

Screw Size 

Suggested 

Torque 

RSP-750 / 1000 / 1500 / 2000 / 2400 / 3000 
SE-450 / 1000 / 1500 
HEP-600

HRP-300

HRPG-300

MSP-300 

SP-480

SP-750

SPV-1500

USP-500

RST-10000 

M4 10-12kgf-cm 

HRP-075 / 100 / 150 / 200

HRPG-150 / 200 

LRS-035 / 050 / 075 / 100 / 150 / 150F / 200 / 350 
MSP-100 / 200 
NED-035 / 050 / 075 / 100

NET-035 / 050 / 075 

NES-025 / 035 / 050 / 075 / 100 / 150 / 200 / 350 
QP-200 / 320 / 375 
RD-050 / 065 / 085 / 125

RID-050 / 065 / 085 / 125 

RS-035 / 050 / 075 / 100 / 150 
RSP-075 / 100 / 150 / 200 / 320 
SP-075 / 100 / 150 / 200 / 240 / 320

SPV-150/300 

SE-100 / 200 / 350

HSP-250

PSP-600 

M3.5 8-10 

kgf-cm 

RSP-1600 
RD-035

RT-050 / 065 / 085 / 125 

RQ-050 / 065 / 085 / 125 
TP-075 / 100 / 150

QP-100 / 150 

RS-015 / 025 
NES-015

USP-150 

M3 6-8 

kgf-cm 

ERP-350 
HDP-190 / 240 
NEL-200 / 300 

#6 8-10 

kgf-cm 

ENP-120 / 180 / 240 / 360 

M2.6 

4-5 kgf-cm 

Summary of Contents for HEP-1000

Page 1: ...erature may increase the internal component temperature and will require a de rating in output current Please refer to the specification sheets to receive the optimum mounting position and information...

Page 2: ...8kgf cm UHP 200A M3 5 13kgf cm M3 5 8kgf cm CSP 3000 M4 10 12kgf cm M6 13kgf cm UHP 500 R 750 1000 M3 5kgf cm M4 10 12kgf cm HEP 600 1000 M4 10 12kgf cm M4 10 12kgf cm 6 Torque can be various due to...

Page 3: ...Note Current each wire carries should be de rated to 80 of the current suggested above when using 5 or more wires connected to the unit Make sure that all strands of each stranded wire enter the termi...

Page 4: ...to earth ground 6 All MW s PSUs are designed in accordance with EMC regulations and the related test reports are available by request Since they are belong to component power supplies and will be inst...

Page 5: ...oducts Appendix B adopting table look up to verify the Environment Friendly Use Period Names and Contents of Hazardous Substances Lists Part Name Hazardous Substances Lead Pb Mercury Hg Cadmium Cd Hex...

Page 6: ...to China s Standardization Administration Releases VOC Standards Standard No Name of the Standard GB 30981 2020 Limit of harmful substances of industrial protective coatings GB 33372 2020 Limits for v...

Page 7: ...eby confirms that MEAN WELL product series comply with Use and Risk Management for Five PBT Chemicals under TSCA section 6 h CAS No Substance Name 1163 19 5 Decabromodiphenyl ether DecaBDE 68937 41 7...

Reviews: