Meade 07002 Installation Instructions Download Page 2

Fig. 2: Thread Latitude Adjustment Screw

Fig. 3: Attach to Tripod

Fig. 4: Attach Azimuth Arm

Fig. 5: Attach Azimuth Base

1

1

1

1

2

2

2

3

4

2

2

2.  Attach the azimuth arm with the spacer block (1, Fig. 4) to the wedge 

body using the two 8-32 x 1/2” flat-head machine screws (2, Fig 4).

3.  Attach the azimuth base (1, Fig. 5) to the tripod using the two 8-32 x 1” 

round-head machine screws (2, Fig 5).

4.  Thread the two azimuth adjustment knobs (3, Fig. 5) into the azimuth 

base, until they just touch the azimuth arm (4, Fig. 5).

USING THE AZIMUTH CONTROL

1.  To adjust the wedge in azimuth, slightly loosen the 3” central manual 

knob and three 5/16” button head screws on the wedge floor. 

NOTE: 

Never adjust the azimuth controls when the 3” central manual knob 
or three 5/16” button head screws are tight. Damage to the wedge 
or hardware may occur.

2.  Rotate the wedge by using the two azimuth knobs(3, Fig 5) in a push-

pull manner.

3.  After positioning the wedge, tighten the central manual knob and three 

5/16” button head screws until firm.

MEADE CUSTOMER SERVICE

If you have a question concerning your Meade Wedge, contact the Meade Instru-

ments Customer Service Department at: 

Telephone: (800) 626-3233 or Email: 

[email protected]

Customer Service hours are 7:00 AM to 4:00 PM, Pacific Time, Monday through 

Friday. In the unlikely event that your Meade Wedge requires factory servicing 

or repairs, write or call the Meade Customer Service Department first, before re

-

turning the telescope to the factory, giving full particulars as to the nature of the 

problem, as well as your name, address, and daytime telephone number. The great 

majority of servicing issues can be resolved by telephone, avoiding return of the 

telescope to the factory. If factory service is required, you will be assigned a Return 

Goods Authorization (RGA) number prior to return.

MEADE LIMITED WARRANTY

Every Meade telescope, spotting scope, and telescope accessory is warranted 

by Meade Instruments Corporation (“Meade”) to be free of defects in materials 

and workmanship for a period of ONE YEAR from the date of original purchase 

in the U.S.A. and Canada. Meade will repair or replace a product, or part thereof, 

found by Meade to be defective, provided the defective part is returned to Me-

ade, freight-prepaid, with proof of purchase. This warranty applies to the original 

purchaser only and is non-transferable. Meade products purchased outside North 

America are not included in this warranty, but are covered under separate warran-

ties issued by Meade international distributors.

RGA Number Required: 

Prior to the return of any product or part, a Return Goods 

Authorization (RGA) number must be obtained from Meade by writing, or calling 

(800) 626-3233. Each returned part or product must include a written statement 

detailing the nature of the claimed defect, as well as the owner’s name, address, 

and phone number.

This warranty is not valid in cases where the product has been abused or mishan-

dled, where unauthorized repairs have been attempted or performed, or where 

depreciation of the product is due to normal wear-and-tear. Meade specifically dis

-

claims special, indirect, or consequential damages or lost profit which may result 

from a breach of this warranty. Any implied warranties which cannot be disclaimed 

are hereby limited to a term of one year from the date of original retail purchase. 

This warranty gives you specific rights. You may have other rights which vary from 

state to state. Meade reserves the right to change product specifications or to dis

-

continue products without notice.

For 07002

REV 02

03/2016

Reviews: