Meaco MeacoMist Deluxe Instruction Manual Download Page 7

 

7

 

 

CONTROL PANEL

 

 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

 

When the % symbol is shown, the data on the digital display will refer to the humidity level in 
the environment.  

 

When the 

°

C symbol is shown, the data on the digital display will refer to the temperature in the 

environment. 

 

 

When the H symbol is shown it means the Timer has been set. Press the Timer button to see 
the number of remaining hours.  

 

The humidity level in  the  environment will show for 10 seconds on the display,  and then the 
temperature of the environment will show for 5 seconds. This will continuously repeat.  

 

POWER BUTTON 

When  the  humidifier  is  first  plugged  in  to  the  mains,  the  machine  will  beep  and  turn  on  in 

Standby Mode. Press the Power Button once, the LED display will light up and the machine will start to 
work. Press the Power Button again, the machine will stop working and go back into Standby Mode.  

 

AUTO MODE 

Press the Auto/Night Button to enter the automatic control mode. In this mode the machine 

will  maintain a relative humidity  level between 50%rh and  60%rh. The  machine will choose  the best 
humidifying method according to the ambient humidity level of the room.  

 

NIGHT MODE

 

Hold the Auto/Night Button down for 3 seconds to enter Night Mode. The lights on the display 

will dim. Press any button to stop Night Mode and the display will brighten.  

 

 

 

 

Summary of Contents for MeacoMist Deluxe

Page 1: ...idifier and Air Purifier Instruction Manual MeacoMist Deluxe Humidifier Please read this instruction manual before using the MeacoMist and keep safe for future reference Thank you for choosing Meaco we really appreciate it ...

Page 2: ...ounded and able to deliver the appropriate voltages to the unit Handle with Care Do not drop throw or crash the unit Rough treatment can damage the components or wiring and create a hazardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the unit cannot fall and cause injury Keep Out of Water Never operate the un...

Page 3: ...rminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly 5 Only ever us...

Page 4: ... so it is important not to set the target humidity level too high The ultraviolet lamp in the base of the humidifier when turned on will kill bacteria and germs that might be present in the water to ensure that the mist that is humidified is as clean as possible As part of this process the plastic in the base will discolour and will turn yellow This is not a fault and is impossible to prevent it i...

Page 5: ... 2 Top cover 3 Cleaning brush 4 Water tank handle 5 Water tank 6 Water level window 7 Water tank cap 8 Water housing 9 Control panel 10 Air outlet 11 Base 12 HEPA filter 13 Filter cover 14 Legs 15 Aroma box 16 Power cord 17 Humidity Sensor ...

Page 6: ...TOP COVER WATER TANK BASE UNDERNEATH Handle Mist nozzle Water tank cap Low water level sensor Temperature and humidity sensor PTC heater Ultrasonic pad Water tank sensor Air outlet Drain hole safety feature Aroma Box HEPA filter cover ...

Page 7: ...BUTTON When the humidifier is first plugged in to the mains the machine will beep and turn on in Standby Mode Press the Power Button once the LED display will light up and the machine will start to work Press the Power Button again the machine will stop working and go back into Standby Mode AUTO MODE Press the Auto Night Button to enter the automatic control mode In this mode the machine will main...

Page 8: ...utton down again for 3 seconds to turn the ioniser off WARM MIST Press the Warm Mist Button to start the warm mist function The PTC element in the machine will start working and the mist will become warm Three vertical lines will appear on the display to confirm that warm mist has been set Activating warm mist will increase the humidification output Press the Warm Mist Button again to stop this fu...

Page 9: ...e top cover and water tank from the base 3 Turn the water tank upside down and unscrew the water tank cap removing it from the water tank The calcium carbonate filter will be attached to the water tank cap 4 Fill the water tank with water screw the water tank cap back in place and securely place the water tank back onto the base The water tank level can be viewed through the window on the left han...

Page 10: ...box Put the aroma box back into the machine The aroma function will automatically work when the machine is turned on To stop the aroma function or when the machine is not in use for a long period of time remove the sponge from the aroma box and clean it Re insert the aroma box into the machine 9 Choose your desired setting using the control panel see pages 7 and 8 for more information 10 Please no...

Page 11: ... 0 hours Press the power button again and the humidifier will run as per before ULTRASONIC PAD AND PTC HEATER The ultrasonic pad and PTC heater can be located in the base of the humidifier The ultrasonic pad vibrates at high speed in order to turn water into mist The PTC heater heats up the water when the warm mist option is chosen In areas where the water quality is hard limescale will form on th...

Page 12: ...ipe the inside of the base using a damp cloth The inside of the base must be cleaned weekly Please note any yellowing of the plastic is normal and is caused by the UV lamp working correctly CALCUIM CARBONATE FILTER The calcium carbonate filter can be found inside the water tank attached to the water tank cap To regenerate the calcium carbonate filter sit the filter in water that is 5 salt for 24 h...

Page 13: ...oal filter can be found underneath the base of the humidifier and must be replaced when the colour changes from white to dark grey this will roughly be every 6 months To remove the HEPA charcoal filter press the filter cover open Remove plastic wrapping from the replacement HEPA charcoal filter before installing The replacement HEPA charcoal filter must be inserted so the HEPA white side is facing...

Page 14: ...ower 25W 105W Noise Level Maximum 35dB A Maximum 45dB A Aroma Diffuser Yes Ioniser Yes Ultraviolet Water Sterilisation Yes Timer Yes between 1 and 10 hours Night Mode Yes Adjustable Humidity Level Yes between 40 rh and 80 rh Auto Shut Off Yes HEPA Filter Yes Carbon Filter Yes Dimensions HWD 335 x 255 x 150 mm Nett Weight 2050g ...

Page 15: ...e water is dirty Clean the water tank see page 12 and replace the water The machine is noisy The water tank is in the incorrect position Make sure the water tank is securely in place There is not enough water in the water tank Fill the water tank with more water see page 9 The machine is on an uneven surface Place the machine on a flat stable surface The HEPA charcoal filter is blocked Replace the...

Page 16: ...d by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation including consequential damage will not be entertained 9 Using a third party switching device that turns the humidifier on or off via the mains will invalidat...

Page 17: ...e harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Reviews: