![Me TRACK-Guide II Installation And Operating Instructions Manual Download Page 66](http://html1.mh-extra.com/html/me/track-guide-ii/track-guide-ii_installation-and-operating-instructions-manual_1757540066.webp)
10
Serial Interface application
Transfer target rates via LH5000
66
V7.20160121
30302710-02-EN
Serial Interface application
The "Serial Interface" application is used to enable communication between the terminal and a non-
ISOBUS compatible on-board integrated display/controller.
This interface enables you to use all of the applications together with the GPS signal and the on-
board integrated display/controllers, in order to:
▪ Transfer target rates (using the LH-5000 protocol or the ASD protocol); [
▪ Switch sections on and off (using the ASD protocol). [
So that you do not need to reconfigure the application each time, you can create an individual profile
for each on-board integrated display/controller.
Transfer target rates via LH5000
Tested on-board integrated display/controllers*
Manufacturer
On-board dis-
play/controller
Software version
Baud rate
RAUCH
Quantron A
V1.20.00
9600
RAUCH
Quantron E
V3.51.00
9600
RAUCH
Quantron E2
V2.10.00
9600
RAUCH
Quantron S
V3.90.00
9600
RAUCH
Quantron S2
V1.00.05
9600
ME
Spraylight
V02.00.10
9600
* - Only on-board integrated display/controllers are listed for which we were able to determine that the
serial interface was functional. Results may differ with different software versions.
You have checked whether you need to activate the LH5000 protocol on the on-board integrated
display/controller. If yes, you have activated the protocol.
1. Connect the on-board integrated display/controller to the terminal. [
2.
- Switch on the terminal.
3. Open the Serial Interface application:
| SerialInterf
4.
- Open the list of implement profiles.
5.
- Add a new implement profile.
⇨
A new implement profile appears on the screen.
6. Configure the parameters as shown in the following steps.
7. "Operating Mode" -> "Target Rate Transfer"
8. "Protocol" -> "LH5000"
10
10.1