background image

HOMEDICS 

meˉ 

12

GB 

Skin Sensitivity Test

Before using the system for the first time, choose a small area close to the area you 

intend to treat, for the purpose of performing a skin sensitivity test. Follow the treatment 

instructions below. After the skin test, wait 30 minutes and check your skin for any 

reaction. If the skin appears normal and there is no redness or other skin reaction, then 

you are ready to perform a full treatment to the rest of the body area. Choose the elōs 

setting that did not result in any reaction when performing a complete treatment .  

Treatment

Step 1:

 Shave or remove with an epilator any visible hair in the area you want to treat . 

For your convenience, you can use the mē epilator or shaver accessories to remove 

hair (sold separately). If you do so, there is no need for preparations before the 

treatment, only make sure the hair is no longer than 0.5 cm. Remove the protective 

cap, and insert the epilator or shaver cartridge instead. 

If you do not use the designated mē system shaver or epilator, shave any hairs with 

a razor or electric shaver . Shaving hair in the treatment areas should minimize the 

discomfort felt from the flashes. 

Make sure that the protective cap (provided) is inserted. The system will not work if the 

protective cap or epilator/shaver accessory is not in place .

Note: In order to treat blond, grey, red and light brown hair, it is recommended to use the epilator 

along with the elōs cartridge, for better results.

Step 2:

 Clean your skin and dry it with a towel .

Step 3:

 Turn on the mē system. Select the Low energy level setting. The device will not 

work if you do not select an elōs setting. 

If there is little or no discomfort or reaction (except for slight redness), then raise the 

energy level to the Medium or High setting .

Step 4:

 If you also use the designated shaver/ epilator, press the epilator/shaver 

activation button on the control panel once to run the epilator mechanism at low 

speed. If desired, press it again to run the epilator at high speed. The shaver cartridge 

operates only at Speed level 1 .

Summary of Contents for ELOS

Page 1: ...User Guide el sTM professional hair removal system...

Page 2: ...t safety information 7 Possible side effects and skin reactions 10 How to use your m system 11 Treating Facial Hair 14 Cleaning and storage 18 How To Replace Your Cartridge Shaver Epilator Face adapto...

Page 3: ...by adult men and women For more information about m visit us at www hoMedics co uk Effective Prevention of Hair Re Growth Hair reduction is a gradual and cumulative process Our clinical studies have s...

Page 4: ...for use on ALL hair colours Note For effective results epilator attachment is required for body treatment of naturally light blond red and white grey hair Epilator should not be used on the face Body...

Page 5: ...is destroyed thereby removing and reducing the amount of hair you re left with in the treated area el s technology can even be used safely and effectively on most skin types Hair Growth Cycle Every ha...

Page 6: ...ging of your m you will find the following m system with one cartridge and protective cap already installed Power Cord User Guide Cleaning Brush Goggles Additional Accessories Sold separately Shaver E...

Page 7: ...ts 1 Base unit 2 Cradle 3 Control panel with power button el s energy setting buttons indicator for the percentage of pulses in the cartridge shaver epilator activation button 4 Applicator hand piece...

Page 8: ...e cartridge comes attached to the applicator and is preloaded with light pulses You will need to replace the cartridge when the Empty indicator light on the base unit is red 4 Cartridge activation but...

Page 9: ...t before you expose treated skin to the sun or tan with artificial light Even after 24 hours make sure that the treated skin is not red from the treatment before you expose it to the sun Be sure to ca...

Page 10: ...cause electrocution or electric shock DO NOT use m where it can come into contact with liquids or become wet sink bath shower This can cause electric shock If the system is dropped into liquid unplug...

Page 11: ...ht treatment uncomfortable or cause skin swelling blisters or infection In order to determine if you can use m perform a test on a small patch of skin Then wait 30 minutes to see if any skin reactions...

Page 12: ...or Redness of the skin May occur either at the time of treatment or after If there is no improvement within 24 hours consult your doctor Itching of the treated area Cool the area with cold compresses...

Page 13: ...r is placed in its cradle before turning on the m 5 Press the power button to turn the system on Wait until the indicator next to the power button turns green Now the system is ready for use 6 Set the...

Page 14: ...epilator or shaver cartridge instead If you do not use the designated m system shaver or epilator shave any hairs with a razor or electric shaver Shaving hair in the treatment areas should minimize th...

Page 15: ...have been emitted for one continuous minute To turn the applicator back on press the activation button located on the upper part of the applicator DO NOT hold the applicator window still over one spo...

Page 16: ...mmended to use the face adaptor but it is also possible to treat without The face adaptor can be purchased separately visit www hoMedics co uk to purchase The face adaptor has been designed to accommo...

Page 17: ...tan fades prior to performing a test pulse on a hidden area i e under the chin Evaluate the area after 3 days to ensure no side effects have occurred and only then start treatment If you have undergo...

Page 18: ...manent DO NOT treat the beard area in men This might create undesirable hair removal results DO NOT treat over moles or birth marks Protect small areas of sensitive skin such as moles birthmarks etc b...

Page 19: ...ect an el s setting Step 6 Put on the provided eye goggles or sunglasses Eye protection is recommended as treating near your eyes may cause temporary discomfort Step 7 Press the cartridge activation b...

Page 20: ...or shaver Remove the shaver or epilator from the applicator and place the protective cap instead Use the supplied cleaning brush to clean the accessories It is recommended to use a soft tissue or a no...

Page 21: ...to page 20 3 Take the new cartridge out of its protective container Try to avoid touching the glass Fingerprints or oils from your skin interfere with light passing through the glass and this will red...

Page 22: ...ake sure you place the protective cap in place of the used cartridge to protect the system inner parts b Please follow the regulations where you live for disposal of electric systems when recycling or...

Page 23: ...igned with universal voltage That means that you can use the system all over the world You will need to use an adaptor for the plug since electric wall outlets vary by country Make sure that m system...

Page 24: ...that the el s cartridge is active Error light is blinking in red cartridge buttons blink as well Ambient room temperature is too high Move to a cooler area with a room temperature of less than 86 deg...

Page 25: ...24 hours after a treatment stop using m and contact your doctor or Customer Support I barely see any hair reduction Make sure to follow the protocol suggested and to use the treatment duration time su...

Page 26: ...f products damaged by these modifications is not covered under this guarantee HoMedics shall not be responsible for any type of incidental consequential or special damages To obtain guarantee service...

Page 27: ...ny patent or patent rights of Syneron Medical Ltd Syneron Medical Ltd has patents pending patent applications trademarks copyrights or other intellectual property rights covering the me product The pu...

Page 28: ...turer s name address the system s part serial numbers electrical requirements and regulatory standards that the system is designed to comply with Degree of protection against ingress water ordinary Th...

Page 29: ...IEC 60601 1 11 EMC Standards EN 61000 6 1 2007 EN 61000 6 3 2007 Electrical Rating 100 240 VAC 50 60 Hz Dimensions and weight 20 5 x 15 x 9 cm W x L x H 1 17 Kg Acceptable Environmental Conditions Sto...

Page 30: ...erved Syneron and m are trademarks of Syneron Beauty Ltd and may be registered in certain jurisdictions Publication 1212 REV 01 Validate your warranty for m and receive product updates and special off...

Reviews: