Pin assignment
The connection of the sensors, the rechargeable battery and the voltage for charge / trickle
charging of the rechargeable battery is done via solder pads.
For the configuration, solder bridges are closed, e.g. for configuring the inputs of the inputs
for strain gage half bridges or strain gage quarter bridges
Strain gauge full bridges
Designation
Ch 1 Ch 2 Ch 3 Ch 4 Ch 5 Ch 6
positive bridge supply US+
11
10
9
3
2
1
positive bridge output
UD+
17
16
15
14
13
12
negative bridge output
UD-
33
31
29
22
20
18
negative bridge supply
US-
44
43
42
36
35
34
ME-Meßsysteme GmbH
Neuendorfstr. 18a
Tel.: +49 3302 89824 60
Mail: [email protected]
16761 Hennigsdorf
Fax: +49 3302 89824 69
Web: www.me-systeme.de
9
+Us
R1
R2
R4
R3
-Ud
+Ud
-Us