The indoor unit is equipped with auto-restart function, which is carried out through an auto-restart
module. In case of a sudden power failure, the module memorizes the setting conditions before
the power failure. The unit will resume the previous operation setting (not including swing function)
automatically after 3 minutes when power returns.
If the memorization condition is forced cooling mode, the unit will run in cooling mode for 30
minutes and turn to auto mode as 24
℃
setting temp.
If AC is off before power off and AC is required to start up now, the compressor will have 1 minute
delay when power on. Other conditions, the compressor will have 3 minutes delay when restarts.
8.4.10 Refrigerant Leakage Detection
With this new technology, the display area will show “EC” when the outdoor unit detects refrigerant
leakage.
8.4.11 Louver Position Memory Function
When starting the unit again after shutting down, its louver will restore to the angle originally set by
the user, but the precondition is that the angle must be within the allowable range, if it exceeds, it
will memorize the maximum angle of the louver. During operation, if the power fails or the end
user shuts down the unit in the turbo mode, the louver will restore to the default angle.
8.4.12 8
℃
Heating(optional)
In heating operation, the preset temperature of the air conditioner can be as lower as 8
℃
, which
keeps the room temperature steady at 8
℃
and prevents household things freezing when the
house is unoccupied for a long time in severe cold weather.
8.4.9 Auto-Restart function