MDV M0BA30-11CFN1-MQ0W Technical Manual Download Page 1

TM_AB_R410A_INV_US_NA_2009

R410A INVERTER CONTROL 

TECHNICAL MANUAL

Summary of Contents for M0BA30-11CFN1-MQ0W

Page 1: ...TM_AB_R410A_INV_US_NA_2009 R410A INVERTER CONTROL TECHNICAL MANUAL...

Page 2: ...Noise Criterion Curves 9 Electrical Characteristics 2 Product Features 49 1 Operation Modes and Functions 2 Remote Controller Functions 3 Installation 56 1 Installation Overview 2 Location Selection...

Page 3: ...rence 4 2 General Specifications 5 3 Dimensional Drawings 11 4 Electrical Wiring Diagrams 13 5 Refrigerant Cycle Diagrams 20 6 Capacity Tables 21 7 Noise Criterion Curves 42 8 Electrical Characteristi...

Page 4: ...Model Indoor Unit Model Capacity Btu h Power Supply MOBA30 12CFN1 BP0W MSABB 12CRDN1 BP0W 12k 1 115V 60Hz MOX130 11CFN1 BT0W MSABB 11CRFN1 BT0W 11k MOBA30 09CFN1 MQ0W MSABA 09CRDN1 MP0W 09k 1 220 230V...

Page 5: ...ube 7 Inner groove tube Coil length x height x width mm 605x210x26 74 605x84x26 74 605x210x26 74 605x84x26 74 Number of circuits 2 2 Indoor air flow Hi Mi Lo m3 h 400 350 250 595 496 378 CFM 235 206 1...

Page 6: ...type 14 x3 no plug 14 x3 no plug Thermostat type Remote Control Remote Control Operation temperature 17 30 17 30 Ambient temperature Indoor cooling heating C 17 32 17 32 Outdoor cooling heating C 15...

Page 7: ...25x84x13 37 525x105x26 7 4 525x105x26 74 605x210x26 74 605x84x26 74 605x210x26 74 605x84x26 74 Number of circuits 2 2 2 Indoor air flow Hi Mi Lo m3 h 410 350 250 476 422 288 550 430 300 CFM 241 206 14...

Page 8: ...Connection wiring 16 x4 16 x4 16 x4 Plug type 14 x3 no plug 14 x3 no plug 14 x3 no plug Thermostat type Remote Control Remote Control Remote Control Operation temperature 17 30 17 30 17 30 Ambient te...

Page 9: ...il length x height x width mm 750x210x26 74 750x126x26 74 820x210x26 74 820x126x26 74 Number of circuits 4 4 Indoor air flow Hi Mi Lo m3 h 900 750 600 988 776 562 CFM 529 441 353 581 456 331 Indoor so...

Page 10: ...g type 14 x3 no plug 14 x3 no plug Thermostat type Remote Control Remote Control Operation temperature 17 30 17 30 Ambient temperature Indoor cooling heating C 17 32 17 32 Outdoor cooling heating C 15...

Page 11: ...ensional Drawings 3 1 Indoor Unit Capacity Btu h Unit W D H 9k mm 722 187 290 inch 28 43 7 36 11 42 11k 12k mm 802 189 297 inch 31 57 7 44 11 69 18k mm 965 215 319 inch 37 99 8 46 12 56 22K mm 1080 22...

Page 12: ...11CFN1 MQ0W MOBA30 17CFN1 MR0W mm 770 300 555 840 487 298 322 inch 30 3 11 8 21 9 33 1 19 2 11 7 12 7 MOX130 11CFN1 BT0W MOX130 11CFN1 MT0W mm 720 270 495 790 452 255 281 inch 28 35 10 63 19 49 31 10...

Page 13: ...ow Green Conductor ION Positive and Negative Ion Generator CAP Capacitor PLASMA Electronic Dust Collector L LIVE N NEUTRAL Heater The Electric Heating Belt of Indoor Unit T1 Indoor Room Temperature T2...

Page 14: ...Specifications Page 14 MSABB 11CRFN1 BT0W MSABB 11CRFN1 MT0W MSABD 17CRFN1 MQ0W...

Page 15: ...Specifications Page 15 MSABE 22CRDN1 MS0W...

Page 16: ...Alternating Current FAN DC FAN Direct Current FAN CT1 AC Current Detector COMP Compressor T3 Coil Temperature of Condenser T4 Outdoor Ambient Temperature TH Compressor Suction Temperature TP Compress...

Page 17: ...Specifications Page 17 MOBA30 12CFN1 BP0W MOX130 11CFN1 MT0W...

Page 18: ...Specifications Page 18 MOX130 11CFN1 BT0W MOBA30 09CFN1 MQ0W M0BA30 11CFN1 MQ0W...

Page 19: ...Specifications Page 19 MOBA30 17CFN1 MR0W MOCA30 22CFN1 MR0W...

Page 20: ...h Piping length m ft Elevation m ft Additional Refrigerant Gas Liquid Rated Max Rated Max 9k 9 52 3 8 6 35 1 4 5 16 4 25 82 0 10 32 8 15g m 0 16oz ft 11k 12k 12 7 1 2 6 35 1 4 5 16 4 25 82 0 10 32 8 1...

Page 21: ...T 0 67 0 72 0 77 0 81 0 58 0 62 0 67 0 71 0 54 0 58 0 62 0 67 0 43 0 47 0 51 0 55 PI 0 84 0 85 0 85 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 0 84 68 TC 3 53 3 54 3 54 3 54 3 75 3 75...

Page 22: ...1 0 88 0 57 0 63 0 69 0 75 0 51 0 57 0 63 0 69 0 39 0 44 0 50 0 56 PI 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 86 0 85 0 85 0 85 0 85 68 TC 3 60 3 60 3 60 3 60 3 81 3 81 3 81 3 81 3 92...

Page 23: ...0 71 0 38 0 44 0 50 0 56 PI 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 0 87 68 TC 3 66 3 66 3 66 3 69 3 86 3 86 3 86 3 86 3 98 3 98 3 98 3 98 4 30 4 30 4 30 4 30 S T 0...

Page 24: ...5 0 92 0 57 0 64 0 71 0 78 0 51 0 58 0 65 0 72 0 37 0 44 0 50 0 57 PI 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 68 0 68 0 68 0 68 68 TC 3 38 3 37 3 37 3 40 3 59 3 60 3 60 3 60 3 69...

Page 25: ...3 1 00 0 59 0 68 0 77 0 86 0 52 0 61 0 70 0 79 0 35 0 44 0 52 0 60 PI 0 71 0 71 0 71 0 71 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 0 70 68 TC 3 46 3 46 3 49 3 51 3 66 3 66 3 66 3 66 3 74...

Page 26: ...0 84 0 34 0 44 0 54 0 63 PI 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 71 0 71 0 71 0 71 68 TC 3 51 3 54 3 57 3 60 3 72 3 72 3 72 3 74 3 83 3 83 3 83 3 83 4 12 4 12 4 12 4 12 S T 0...

Page 27: ...1 0 87 0 57 0 62 0 69 0 75 0 51 0 57 0 63 0 69 0 39 0 44 0 50 0 55 PI 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 0 57 68 TC 2 62 2 61 2 61 2 61 2 78 2 78 2 78 2 78 2 87...

Page 28: ...9 0 97 0 58 0 66 0 75 0 83 0 51 0 59 0 67 0 75 0 36 0 44 0 51 0 58 PI 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 58 0 57 0 57 0 57 0 57 68 TC 2 70 2 70 2 72 2 75 2 84 2 84 2 84 2 84 2 92...

Page 29: ...0 80 0 35 0 44 0 52 0 61 PI 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 0 59 68 TC 2 75 2 75 2 78 2 81 2 90 2 90 2 90 2 90 2 98 2 98 2 98 2 98 3 21 3 21 3 21 3 21 S T 0...

Page 30: ...3 0 90 0 57 0 63 0 70 0 76 0 51 0 58 0 64 0 70 0 38 0 44 0 50 0 56 PI 0 73 0 73 0 73 0 73 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 72 0 73 0 73 0 73 0 73 68 TC 3 38 3 37 3 37 3 40 3 59 3 60 3 60 3 60 3 69...

Page 31: ...1 0 87 0 57 0 63 0 69 0 75 0 51 0 57 0 63 0 69 0 39 0 44 0 50 0 55 PI 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 73 0 73 0 73 0 73 68 TC 3 46 3 46 3 46 3 46 3 66 3 66 3 66 3 66 3 74...

Page 32: ...0 73 0 37 0 44 0 50 0 57 PI 0 76 0 76 0 76 0 76 0 75 0 75 0 75 0 75 0 75 0 75 0 75 0 75 0 75 0 75 0 75 0 75 68 TC 3 51 3 51 3 51 3 54 3 72 3 72 3 72 3 72 3 83 3 83 3 83 3 83 4 12 4 12 4 12 4 12 S T 0...

Page 33: ...0 0 86 0 57 0 62 0 68 0 74 0 52 0 57 0 63 0 68 0 40 0 45 0 50 0 55 PI 0 67 0 67 0 67 0 67 0 66 0 66 0 66 0 66 0 66 0 66 0 66 0 66 0 66 0 66 0 66 0 66 68 TC 3 38 3 37 3 37 3 37 3 59 3 60 3 60 3 60 3 69...

Page 34: ...8 0 96 0 58 0 66 0 74 0 81 0 51 0 59 0 67 0 74 0 36 0 44 0 51 0 58 PI 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 68 0 69 0 69 0 69 0 69 68 TC 3 46 3 46 3 46 3 49 3 66 3 66 3 66 3 66 3 74...

Page 35: ...0 81 0 35 0 44 0 53 0 62 PI 0 70 0 70 0 70 0 70 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 69 0 70 0 70 0 70 0 70 68 TC 3 51 3 51 3 54 3 57 3 72 3 72 3 72 3 74 3 83 3 83 3 83 3 83 4 12 4 12 4 12 4 12 S T 0...

Page 36: ...7 0 95 0 58 0 65 0 73 0 80 0 51 0 59 0 66 0 73 0 37 0 44 0 51 0 57 PI 1 10 1 11 1 11 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 10 1 09 1 09 1 09 1 09 68 TC 5 00 5 01 5 01 5 07 5 30 5 30 5 30 5 30 5 44...

Page 37: ...4 1 00 0 59 0 69 0 78 0 87 0 52 0 61 0 70 0 79 0 35 0 44 0 52 0 61 PI 1 13 1 13 1 13 1 13 1 13 1 13 1 13 1 13 1 12 1 12 1 12 1 12 1 13 1 13 1 13 1 13 68 TC 5 10 5 10 5 16 5 21 5 39 5 39 5 39 5 39 5 56...

Page 38: ...0 85 0 34 0 44 0 54 0 64 PI 1 15 1 15 1 15 1 15 1 15 1 15 1 15 1 15 1 14 1 14 1 14 1 14 1 15 1 15 1 15 1 15 68 TC 5 18 5 24 5 30 5 36 5 50 5 50 5 50 5 56 5 64 5 64 5 64 5 64 6 08 6 08 6 08 6 08 S T 0...

Page 39: ...9 0 85 0 57 0 62 0 68 0 73 0 52 0 57 0 63 0 68 0 40 0 45 0 50 0 55 PI 1 37 1 37 1 37 1 37 1 36 1 36 1 36 1 36 1 37 1 37 1 37 1 37 1 36 1 36 1 36 1 36 68 TC 6 46 6 47 6 47 6 47 6 85 6 85 6 85 6 85 7 05...

Page 40: ...6 0 94 0 57 0 65 0 72 0 80 0 51 0 58 0 66 0 73 0 37 0 44 0 50 0 57 PI 1 40 1 40 1 40 1 40 1 39 1 39 1 39 1 39 1 39 1 39 1 39 1 39 1 39 1 39 1 39 1 39 68 TC 6 59 6 59 6 59 6 65 6 97 6 97 6 97 6 97 7 20...

Page 41: ...0 79 0 35 0 44 0 52 0 61 PI 1 43 1 43 1 43 1 43 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 1 42 68 TC 6 71 6 71 6 76 6 82 7 11 7 11 7 11 7 11 7 31 7 31 7 31 7 31 7 86 7 86 7 86 7 86 S T 0...

Page 42: ...e unit Data is valid at free field condition Data is valid at nominal operation condition Reference acoustic pressure OdB 20 Pa Sound level will vary depending on a range of factors such as theconstru...

Page 43: ...Specifications Page 43 MSABB 12CRDN1 BP0W MSABB 11CRFN1 BT MSABA 09CRDN1 MP0W MSABB 12CRDN1 MP0W...

Page 44: ...Specifications Page 44 MSABB 11CRFN1 MT0W MSABD 17CRFN1 MQ0W MSABE 22CRDN1 MS0W 7 2 Outdoor Unit...

Page 45: ...lid at free field condition Data is valid at nominal operation condition Reference acoustic pressure OdB 20 Pa Sound level will vary depending on arrange off actors such as the construction acoustic a...

Page 46: ...Specifications Page 46 MOBA30 12CFN1 BP0W MOX130 11CFN1 BT0W MOBA30 09CFN1 MQ0W M0BA30 11CFN1 MQ0W...

Page 47: ...Specifications Page 47 MOX130 11CFN1 MT0W MOBA30 17CFN1 MR0W MOCA30 22CFN1 MR0W...

Page 48: ...nit Power Supply Compressor OFM Phase Hz Voltage MCA MFA MSC RLA Qty kW FLA MOBA30 12CFN1 BP0W 1 60 115 15 20 9 5 1 0 034 0 6 MOX130 11CFN1 BT0W 19 30 14 3 1 0 034 0 6 MOBA30 09CFN1 MQ0W 1 60 208 230...

Page 49: ...Auto mode 52 1 8 Drying Mode 52 1 9 Forced Operation Function 52 1 10 Timer Function 52 1 11 Sleep Function 52 1 12 Auto Restart Function 53 1 13 Refrigerant Leakage Detection 53 1 14 Louver Position...

Page 50: ...tarts the louver is automatically activated and the indoor fan will operate after a period of 7 seconds If the unit is in heating mode the indoor fan is regulated by the anti cold wind function Compre...

Page 51: ...the former frequency When T3 TP4 for 9 seconds the compressor will stop until T3 TP2 1 1 5 4 Evaporator Temperature Protection When evaporator temperature drops below a configured value the compresso...

Page 52: ...mode operates the same as normal auto mode with a preset temperature of 24 C The unit exits forced operation when it receives the following signals Switch on Switch off Timer on Timer off Changes in...

Page 53: ...range if it exceeds it will memorize the maximum angle of the louver During operation if the power fails or the end user shuts down the unit in the turbo mode the louver will restore to the default a...

Page 54: ...lt in insufficient cooling If you feel uncomfortable just press the ECO button again to stop it 6 CLEAN AIR Button applicable to RG51F3 EU1 Disable Active clean air function When the clean air functio...

Page 55: ...e Turbo function Turbo function enables the unit to reach the preset temperature at cooling or heating operation in the shortest time if the indoor unit does not support this function there is no corr...

Page 56: ...tion Selection 60 3 Indoor Unit Installation 61 4 Outdoor Unit Installation 66 5 Refrigerant Pipe Installation 68 6 Vacuum Drying and Leakage Checking 69 7 Additional Refrigerant Charge 70 8 Electrica...

Page 57: ...ptional Parts Remote controller holder 1 Dry battery AAA LR03 2 Seal 1 for cooling heating models only Drain joint Owner s manual Installation manual p m i f q J q v m b o l l j f o l k a f q f l k b...

Page 58: ...tion Page 58 1 Installation Overview Installation Order Select Installation Location Attach Mounting Plate Drill Wall Hole Determine Wall Hole Position 1 2 3 4 12cm 4 75in 2 3m 90 55in 12cm 4 75in 15c...

Page 59: ...Installation Page 59 Mount Indoor Unit STEP 8 Connect Piping Connect Wiring Prepare Refrigerant piping 5 6 7 8 9 W rap Piping and Cable not applicable for some locations in the US...

Page 60: ...minimum distance between the outdoor unit and walls described in the installation guide does not apply to airtight rooms Be sure to keep the unit unobstructed in at least two of the three directions M...

Page 61: ...te 3 Width of indoor unit relative to plate 4 Height of indoor unit relative to plate 5 Recommended position of wall hole both to the left and right of mounting plate 6 Relative distances between scre...

Page 62: ...etc 1 Based on the position of the wall hole relative to the mounting plate choose the side from which the piping will exit the unit 2 If the wall hole is behind the unit keep the knock out panel in p...

Page 63: ...unit 2 Attach drain hose extension purchased separately to the end of drain hose 3 Wrap the connection point firmly with Teflon tape to ensure a good seal and to prevent leaks 4 For the portion of the...

Page 64: ...unit has an auxiliary electric heater it must be installed at least 1 meter 40in away from any combustible materials 12 BEFORE PERFORMING ANY ELECTRICAL OR WIRING WORK TURN OFF THE MAIN POWER TO THE...

Page 65: ...se tightly together Double check that all items are bundled in accordance with the picture above NOTE Drain hose must be on bottom Make sure that the drain hose is at the bottom of the bundle Putting...

Page 66: ...OTE Unit is adjustable Keep in mind that the hooks on the mounting plate are smaller than the holes on the back of the unit If you find that you don t have ample room to connect embedded pipes to the...

Page 67: ...ote that there are two different types of drain joints depending on the type of outdoor unit If the drain joint comes with a rubber seal see Fig A do the following 1 Fit the rubber seal on the end of...

Page 68: ...n line riser The indoor unit is installed higher than the outdoor unit If the outdoor unit is installed higher than the indoor unit It is recommended that vertical suction risers not be upsized Proper...

Page 69: ...ce blockage and copper oxidation Ice blockage shall cause abnormal operation of system while copper oxide shall damage compressor Eliminating the non condensable gas air in system to prevent the compo...

Page 70: ...arge After the vacuum drying process is carried out the additional refrigerant charge process need to be performed The outdoor unit is factory charged with refrigerant The additional refrigerant charg...

Page 71: ...e instructions 8 3 After performing gas leak checks After confirming that the all pipe connection points DO NOT leak replace the valve cover on the outside unit 9 Test Operation 9 1 Before test run On...

Page 72: ...he indoor unit installation process 9 3 If ambient temperature is below 17 C 63 F You can t use the remote controller to turn on the COOL function when the ambient temperature is below 17 C In this in...