Technical Manual
Glass Push-button II Smart & Push-button Smart 86 [Series .02]
MDT technologies GmbH •
51766 Engelskirchen • Papiermühle 1 • Germany
Phone: +49-2263-
880 • [email protected] • www.mdt.de
36
36
As many levels are displayed for setting as have been activated in the "Button/Function setting"
menu.
The following table shows the available settings:
ETS-Text
Dynamic range
[Default value]
Comment
Level 1-3 (Functions 1-4 / 5-8 / 9-12)
Level labelling
any text
[15 Bytes allowed]
Setting the text for the respective
level.
The text is displayed above the level
symbol.
Symbol colour
any colour
Sets the colour for the symbol.
Level symbol
all loaded symbols
Setting of the symbol to be displayed
for the appropriate level.
Table 21: Settings
–
Level setting
4.3.3 Overview: Two-button function / Single-button function
Each pair of buttons can be activated as a single-button function or as a two-button function.
With the
single-button function
, only one button is used for one function.
With the
two-button function
, two buttons are always used for one function and the operating
concept works like a rocker. It is possible to specify for each button which value (On/Off, Up/Down,
Brighter/Darker, etc.) it is to send.
A
function name
can be set for both, the single-button function and the two-button function. The
button labelling, due to the smaller space on the display is only possible for the two-button function.
Up to 20 characters are allowed for the function name.
Only with the two-button function is it possible to give the left and right buttons their own names. Up
to 6 characters are permitted for the
button labelling
:
Figure 15: Settings
–
Button labelling - Two-button function
The functions of the single-button function and the two-button function are described in more detail
in chapter
. At the beginning of each function description, it is also indicated
whether this function is available as a single-button function, as a two-button function or for both
operating concepts.