 SYMPTOM

      

PROBLEM

      

RESOLUTION

No Flow

Insufficient Prime

Prime system with water and purge all air from suction piping.
Install check valve.

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.
Clean out leaves or other debris from basket strainer (if applicable).

Air leak

Fix air leaks at fittings, connections, strainer basket etc.  This typically occurs on the intake side.

System Incompatibility

Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.

Low Flow

Air leak

Fix air leaks at fittings, connections, strainer basket etc.  This typically occurs on the intake side.

System Incompatibility

Verify hydraulic compatibility: i.e. pump & pipe are sized for the system.

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Clean out leaves or other debris from basket strainer (if applicable).

Insufficient Prime

Prime system with water and purge all air from suction piping.

Cavitation

Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.

Sporadic Operation

Insufficient Power

Verify power supply and connection from panel to pump.

Verify proper voltage.  Some models are dual voltage (115/230).

Poor Ventilation

Ensure adequate airflow over motor to prevent overheating.

Excessive Noise

Cavitation

Verify airtight plumbing on the suction plumbing especially fittings.
Clean out leaves or other debris from basket strainer (if applicable).
Increase pipe size where possible.
Decrease suction pipe length, reduce the number of elbows, etc.
Verify hydraulic compatibility: i.e. pump and pipe are sized for the system.

Insufficient Power

Verify power supply and connection from panel to pump.
Verify proper voltage.  Some models are dual voltage (115/230).

Flow Restriction

Ensure valves are open.
Ensure plumbing is clear, including suction strainers, check valves, etc.
Verify check valve orientation and direction of permitted flow.

MDM INCORPORATED
3345 N. Cascade Ave • Colorado Springs, CO • 80907
Phone (719) 634-8202 • Fax (866) 425-1346
www.mdminc.com • [email protected] 

MAINTENANCE                                                                                         

Lubrication

Motor -  Permanently Lubricated ball bearings - no service required.
Rotary Seal - Requires no lubrication after assembly.

WARNING: EYE PROTECTION IS STRONGLY RECOMMENDED 

*The pump must be drained before servicing or if stored below freezing 
temperatures.  Periodic replacement of seals may be required due to normal 