Temperature control
•
The control can be used to pre-set an interior temperature. According to the size of heating space and prevailing
outdoor temperature, the heater’s temperature can be set within the range of +10 °C to +30 °C.
Control in the heating mode
•
During the heating mode, the room temperature or the temperature of the sucked in heating air is constantly
measured. Based on these and the pre-set temperature by controller switch, heater’s working condition will be
adjusted. If the temperature is higher than the temperature selected on the control element, the heater starts to
regulate its output.
•
There are 4 control stages so that the outflow of heat produced by the heater can be adjusted finely to the
heating requirements. Fan speed and fuel quantity correspond to the control stage.
Ventilating mode
•
Press the ventilation button. Heater will work in ventilation mode. Changeover in mode of ventilation and
burning can be initiated at any time.
Switching off
•
Press the stop working button. Heater switches off, metering pump stops working, and glow plug is switched
on for approx. 40 seconds. After fan runs on for approx. 4 minutes to cool down, heater is shut down when
indicating light goes out.
Trouble shooting and fault guide
Code of
malfunction
Description
Flash frequency
1
Circulation of five short flash, one long flash
––––– — –––––
2
Circulation of five short flash, two long flash
––––– —— –––––
3
Circulation of five short flash, three long flash
––––– ——— –––––
4
Circulation of five short flash, four long flash
––––– ———— –––––
5
Circulation of five short flash, five long flash
––––– ————— –––––
6
Circulation of five short flash, six long flash
––––– —————— –––––
7
Circulation of five short flash, seven long flash
––––– ——————— –––––
8
Circulation of five short flash, eight long flash
––––– ———————— –––––
9
Circulation of five short flash, nine long flash
––––– ————————— –––––
10
Circulation of five short flash, ten long flash
––––– —————————— –––––
Summary of Contents for XT16HR Series
Page 1: ...Phone 1300 494 494 OWNER S MANUAL EDITION 2021 Version 1 XT16HR FAMILY OFFROAD CARAVAN...
Page 39: ...www marketdirect com au Ph 1300 494 494 35...
Page 47: ...www marketdirect com au Ph 1300 494 494 43 12 Volt Wiring Diagram Main Circuit...
Page 48: ...www marketdirect com au Ph 1300 494 494 44 Wiring Diagram Switch Panel...
Page 59: ...www marketdirect com au Ph 1300 494 494 55 Schematic...
Page 68: ...www marketdirect com au Ph 1300 494 494 64 Trouble Shooting Electrical...
Page 78: ...www marketdirect com au Ph 1300 494 494 74 Trip Name Date Km Start Km Finish Cumulative Km...
Page 81: ...www marketdirect com au Ph 1300 494 494 77 Hub Assembly...
Page 82: ...www marketdirect com au Ph 1300 494 494 78 Trailing Arm Bushes...