Limitations
CSP–FF–1
ROTORCRAFT FLIGHT MANUAL
MD 530F Plus
(Model 369FF)
Revision 5
2–6
FAA Approved
2–8. ELECTRICAL SYSTEM LIMITATIONS
Generator limits:
Maximum continuous: 140 amps
140 to 200 amps: 10 minutes
Battery limits:
Flight following a battery overtemperature of 160
°
F (71
°
C) or above is pro+
hibited until the battery has been inspected.
2–9. STARTER LIMITATIONS
If ignition is not attained:
30 seconds ON; 2 minutes OFF
30 seconds ON; 2 minutes OFF
30 seconds ON; 30 minutes OFF
2–10. FUEL SYSTEM LIMITATIONS
Fuel Specifications:
The use of AVGAS (MIL–G–5572) only as an emergency fuel is not
allowed. Unexpected engine flameout may occur.
For additional information on fuels, refer to the appropriate Rolls Royce Opera+
tion and Maintenance Manual.
Primary
Jet A (ASTM D−1655); Jet A−1 (ASTM D−1655); Jet B (ASTM−D−1655)
JP−1 conforming to ASTM D−1655, Jet A or Jet A−1
JP−4 (MIL−DTL−5624); JP−5 (MIL−DTL−5624); JP−8 (MIL−DTL−83133)
Arctic Diesel Fuel DF−A conforming to ASTM D−1655,
Jet A or Jet A−1
Diesel No. 1 conforming to ASTM D−1655, Jet A or Jet A−1
Peoples Republic of China RP−3.
Emergency
WARNING