15
Electrical system
L
Phase
N
Neutral
TA
Room thermostat
IN
Switch ON/OFF
FR
Photo-resistance
MV
Fan Motor
EV1
Solenoid valve
X2 B/5
Power supply connector
Figure 21 - XL 9ERM Electrical system
Figure 11 and Figure 12 show the electrical systems for the XL 9ERM and XL 9SRM heaters. These
electrical systems highlight how all the various parts that contribute to the machine's correct operation have
been connected.
L
Phase
N
Neutral
TA
Room thermostat
IN
Switch ON/OFF
IP
Power switch
FR
Photo-resistance
MV
Fan Motor
EV1
Solenoid valve 1st Flame
stage
EV2
Solenoid valve 2nd Flame
stage
X2 B/5
Power supply connector
Figure 22 - XL 9SRM Electrical system
XL 9ERM
XL 9SRM