Heat Pump Unit
Table 7
shows the LED indicator lights for the heat pump unit under normal operation and fault conditions. The LED
indicator lights are located at the bottom right side of
the indoor unit.
The heat pump units are equipped to maintain selected room temperature by switching automatically to either “cool” or
“heat” mode.
Figure 23. LED Indicator Lights: Normal Operation and
Fault Conditions for Heat Pump Unit
Table 7. LED Indicator Lights: Normal Operation and Fault Conditions for Heat Pump Unit
Cool
Dry
Fan
Heat
Sleep
Mode or Fault
Action
/
Cooling -
Dry
-
Fan
-
/
Heat -
/
Auto mode in heating
operation. *
-
/
Auto mode in cooling
operation. *
-
Compressor
cycling
on
overload
Low outdoor air flow, defective
compressor or overload.
Indoor coil sensor loose
or defective
Attach or replace.
Outdoor
coil
sensor
loose or defective
Attach or replace.
Room air sensor loose
or defective
Attach or replace.
Unit Malfunctions
If in AUTO or SLEEP mode, switch to
Heat, turn SLEEP off, unplug power
cord and plug back in.
If both lights blink with unit in Heat or
Cool and SLEEP off, the problem may
be coil sensor, compressor has tripped
or low refrigerant.
ON
/ ON or OFF
Blinking
* Unit has 10 minutes delay before it will switch between modes.
IM-5WMF(SEER13)-0706
Page 21
Summary of Contents for M5LC10C
Page 6: ...Model M5LC20C 20CR 25C 25CR Outdoor Unit Page 6 IM 5WMF SEER13 0706...
Page 15: ...INDOOR UNIT MODEL M5WM 25F Page 15 IM 5WMF SEER13 0706 OUTDOOR UNIT MODEL M5LC 25C...
Page 16: ...INDOOR UNIT MODEL M5WM 10FR 15FR OUTDOOR UNIT MODEL M5LC 10CR 15CR IM 5WMF SEER13 0706 Page 16...
Page 17: ...INDOOR UNIT MODEL M5WM 20FR IM 5WMF SEER13 0706 Page 17 OUTDOOR UNIT MODEL M5LC 20CR...
Page 18: ...INDOOR UNIT MODEL M5WM 25FR IM 5WMF SEER13 0706 Page 18 OUTDOOR UNIT MODEL M5LC 25CR...