background image

 

                                                      www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd     

     

 

3

 

MH7-WH-WT15

 

N

L

COM

NO

NC

T

Thermostatic 

valve/electric 

ball /pump

 

TT terminal is to be 

connected with an 

external ambient 

temperature sensor

 

10A 

 

MH7-EH-WT15

 

N

L

OUT

T

T

 

Heating film

electric 

radiator

heating cable 

ect

 

TT terminal is to be 

connected with an 

external ambient 

temperature sensor

 

16A 

 

 
                                                            Button & Display                                                 

 

 

 

 

 
                                                                Operation                                                           

 

On/Off operation 

When power on, thermostat displays “OFF”

all outputs are forced off. Touch S3 button to 

switch (manual/off/auto) mode, then press S2 to confirm and proceed power on/off setting. After 

power  on,  device  displays  current  week,  local  time,  working  mode,  current  temperature,  output 

status etc. 

 

Note:After the backlit goes out, please press the button to light up the backlit first, then press the 

button again for corresponding operation. 

 

Temperature setting 

In normal working status, press S4 or S5 button will enter into temperature setting interface. 

The setting range is 5-37 

(41-99℉).

 Then press S4 or S5 can adjust the value. Press S3 or wait 

25 seconds without any key operation will save the setting and return back to the normal operation 

interface.   

Auto Mode: 

The changed value only valid in the current time period for this time, and   

                      the device will not effect the preset time period value . 

Manual Mode: 

The changed value will be valid until next setting.

 

Vacation Mode: 

The changed value will be valid until next setting. 

Summary of Contents for MH7-WH

Page 1: ...16A Self Consumption 1W Internal Temp Sensor NTC 15K External Temp Sensor optional NTC R25 15K B25 50 3550K Working Environment 0 50 0 90 RH Non condensation Temperature Setting 5 37 41 99 Adjustable...

Page 2: ...nsert all wires into the right terminals and tighten screws Wiring diagrams are shown below Step 3 Push the bottom into the junction box and secure it with two screws and then mount the touch panel ba...

Page 3: ...current week local time working mode current temperature output status etc Note After the backlit goes out please press the button to light up the backlit first then press the button again for corres...

Page 4: ...evice will follow the preset time periods and temperature to control heating system automatically Manual Mode Device will follow the manual setting temperature to control the heating system Vacation m...

Page 5: ...In shutdown interface When the built in temperature sensor detect the temperature value 5 device will open anti freeze protection electric heating will be forced open and anti freeze protection icon...

Page 6: ...ND_CLASS_MANUFACTURER_SPECIFI COMMAND_CLASS_TIME COMMAND_CLASS_TIME_PARAMETERS Note This device supports 4 kinds of modes in Z Wave Off mode Heating mode Manual Energy Saving heating mode Auto Away he...

Page 7: ...N This limited warranty shall not apply if i the product was not used in accordance with any accompanying instructions or ii the product was not used for its intended function This limited warranty al...

Page 8: ...5 9 5 16 16 P15 External temperature control switching OFF ON OFF Indoor temperature control ON ON OFF External sensor temperature control P16 External temperature display switching OFF ON OFF Indoor...