background image

www.mcohome.com

User Manual

MCOHome Technology Co., Ltd 2014

5

Z-Wave Operation

Including & Excluding of Z-Wave network

Under the shutdown state, press & hold S2 to enter interface for inclusion or exclusion of

Z-Wave network. Before device included into network, “- - -” will display on the screen. Then
press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID
will display on the screen in a few seconds.

A node ID can always inform us whether the device is in the network or not.

Note: Follow the same steps to exclude the device from the network.

After inclusion, turn off the device and

then turn it on. Now the device is ready to be

operated by controller/ gateway in Z-Wave

network.

Association Group

Thermostat supports 1 association group. A gateway is suggested to associate with this

group. Then if any changes happen, such as: temperature, working mode, etc., the thermostat
will report to this associated device (gateway).

Command Class supported by the device:

COMMAND_CLASS_BASIC;

COMMAND_CLASS_THERMOSTAT_SETPOINT;

COMMAND_CLASS_THERMOSTAT_MODE;

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE;

COMMAND_CLASS_SENSOR_MULTILEVEL;

COMMAND_CLASS_ASSOCIATION;

COMMAND_CLASS_VERSION;

COMMAND_CLASS_MANUFACTURER_SPECIFIC

Note:

This device supports 4 kinds of modes in Z-Wave:

Off

mode;

Heating

mode (Manual);

Energy Saving heating

mode (Auto) ;

Away heating

mode (Vacation).

Users can set these 4 modes via COMMAND_CLASS_THERMOSTAT_MODE. And

COMMAND_CLASS_BASIC can switch among Heating mode & Energy saving heating mode.

COMMAND_CLASS_THERMOSTAT_SETPOINT can be used to set the heating

temperature threshold value in Heating mode or Energy saving heating mode.

1-year Limited Warranty

MCOHome warrants this product to be free from defects in material and workmanship under

normal and proper use for one year from purchase date of the original purchaser. MCOHome will, at its
option, either repair or replace any part of its products that prove defective by reason of improper
workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO
THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE,
MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY,
ABNORMAL

MECHANICAL

OR

ENVIRONMENTAL

CONDITIONS,

OR

ANY

UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not
apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the
product was not used for its intended function. This limited warranty also does not apply to any product
on which the original identification information has been altered, obliterated or removed, that has not
been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary
to Country and other applicable export regulations.

Summary of Contents for MH7-EH-EU

Page 1: ...er Supply AC220V 10 50 60HZ Output MH7 WH EU 5A MH7 EH EU 16A Self Consumption 1W Internal Temp Sensor NTC 15K External Temp Sensor optional NTC R25 15KΩ B25 50 3550K Working Environment 0 50 90 RH Non condensation Temperature Setting 5 37 41 98 Adjustable Dimension 86 86 43mm Hole Pitch 60 61mm Safety Information To protect yourself and others from danger and to protect the device from damage ple...

Page 2: ...mperature It should be away from direct sunlight any cover or any heat source to avoid false signal for temperature control CAUTION Cut off power supply at circuit breaker or fuse before installation to avoid fire shock or death Step 1 Separate the device into two parts the display panel and the bottom Step 2 Insert all wires into the right terminals and tighten screws Wiring diagrams are shown be...

Page 3: ...ged value will be valid until next setting Working explanation MH7 WH EU Indoor temperature setting temperature 0 5 output activated and output icon displays Indoor temperature setting temperature 0 5 output turned off and the icon disappears MH7 EH EU Indoor temperature setting temperature 1 5 output activated and output icon displays Indoor temperature setting temperature output turned off and t...

Page 4: ... next days After all periods set press S1 S2 or wait 8 seconds without any key operation will save the setting and return to normal display Device will operate in accordance with the new setting The default setting is as follow High temperature protection MH7 EH EU ONLY If indoor temperature detected by temperature sensor 55 device will open high temperature protection electric heating will be for...

Page 5: ...ode Heating mode Manual Energy Saving heating mode Auto Away heating mode Vacation Users can set these 4 modes via COMMAND_CLASS_THERMOSTAT_MODE And COMMAND_CLASS_BASIC can switch among Heating mode Energy saving heating mode COMMAND_CLASS_THERMOSTAT_SETPOINT can be used to set the heating temperature threshold value in Heating mode or Energy saving heating mode 1 year Limited Warranty MCOHome war...

Page 6: ... MH7 WH EU 0 5 1 0 10 0 20 MH7 EH EU 1 5 3 P06 Temp differential for turn off device MH7 WH EU 0 5 1 0 10 0 20 MH7 EH EU 0 P07 Anti freeze protection function OF ON OF ON open OF close P08 Anti freeze open temp 5 41 0 10 32 50 P09 Anti freeze close temp 8 46 0 10 32 50 P10 High temp Protection MH7 WH EU 0 function closed 0 99 32 211 MH7 EH EU 55 131 P11 Power failure memory 2 0 2 P12 Reserved 0 0 ...

Reviews: