COMMAND_CLASS_THERMOSTAT_MODE_V2, 

THERMOSTAT_MODE_REPORT 

When thermostat 

mode changes 

COMMAND_CLASS_THERMOSTAT_OPERATING_STA

TE, THERMOSTAT_OPERATING_STATE_REPORT 

When thermostat 

status changes   

COMMAND_CLASS_THERMOSTAT_SETPOINT_V2, 

THERMOSTAT_SETPOINT_REPORT_V2 

When 

temperature 

setpoint changes 

 

 

Command Class supported by the device:

 (All CC supports S2 unauthenticated level)

 

COMMAND_CLASS_VERSION,                   

                         

    COMMAND_CLASS_MANUFACTURER_SPECIFIC,                                                 

    COMMAND_CLASS_POWERLEVEL,                                                 

    COMMAND_CLASS_ASSOCIATION,   

    COMMAND_CLASS_ASSOCIATION_GRP_INFO,                             

    COMMAND_CLASS_BASIC,                                   

    COMMAND_CLASS_FIRMWARE_UPDATE_MD                           

    COMMAND_CLASS_SENSOR_MULTILEVEL_V5,                         

    COMMAND_CLASS_THERMOSTAT_SETPOINT,                           

    COMMAND_CLASS_THERMOSTAT_MODE, 

                             

   

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE,     

     

    COMMAND_CLASS_THERMOSTAT_FAN_MODE, 

                   

COMMAND_CLASS_THERMOSTAT_FAN_STATE, 

               

      COMMAND_CLASS_SUPERVISION, 

                                                   

     

 

Command Class supported by the device:

 (Not supports S2)

 

COMMAND_CLASS_ZWAVEPLUS_INFO     

COMMAND_CLASS_TRANSPORT_SERVICE 

COMMAND_CLASS_SECURITY_2 

 

Note: 

Basic CC is used to control energy saving mode and comfort mode: 

· 

Basic Set (Value = 0x00) = Set Off Mode 

· 

Basic Set (Value = 0xFF) = Set Auto Mode 

· 

Basic Get = Get Report 

· 

Basic Report (Value = 0x00) = Report off Mode 

· 

Basic Report (Value = 0xFF) = Report other Modes   

 

Restoring Factory Settings:

 

1

Remove the device out from Z-Wave network can restore factory setting. 

2

Configure the parameter 10 in secret menu can restore the factory setting also. Please use this 

procedure only when the network primary controller is missing or otherwise inoperable. 

 

                                              1-year Limited Warranty                                                 

 

MCOHome  warrants  this  product  to  be  free  from  defects  in  material  and  workmanship  under 

normal and proper use for one year from purchase date of the original purchaser. MCOHome will, at its 
option,  either  repair  or  replace  any  part  of  its  products  that  prove  defective  by  reason  of  improper 
workmanship or materials. THIS LIMITED WARRANTY  DOES NOT COVER ANY DAMAGE TO 
THIS  PRODUCT  THAT  RESULTS  FROM  IMPROPER  INSTALLATION,  ACCIDENT,  ABUSE, 
MISUSE,  NATURAL  DISASTER,  INSUFFICIENT  OR  EXCESSIVE  ELECTRICAL  SUPPLY, 
ABNORMAL 

MECHANICAL 

OR 

ENVIRONMENTAL 

CONDITIONS, 

OR 

ANY 

UNAUTHORIZED  DISASSEMBLY,  REPAIR  OR  MODIFICATION. This  limited  warranty  shall not 
apply  if:  (i)  the  product  was  not  used  in  accordance  with  any  accompanying  instructions,  or  (ii)  the 
product was not used for its intended function. This limited warranty also does not apply to any product 
on which the original identification information has been altered, obliterated or removed, that has not 
been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary 
to Country and other applicable export regulations. 

Summary of Contents for MH6-HP

Page 1: ...d glass panel with Capacitive touch buttons NTC thermistor Built in Z Wave module Specification Power supply AC24V 50 60Hz Power dissipation 2W Dimension 136 94 26mm Output 1A Resistant load Temperatu...

Page 2: ...id damage Avoid overexertion during operation to protect device from mechanical damage Read all instructions and documentation and save for future reference Installation Wiring CAUTION Cut off power s...

Page 3: ...Cool output Compressor output heat pump G Fan output C 24VAC common Connect only when AC power Y2 Cool output 2 2nd stage compressor output heat pump W2 AUX Heat output 2 Auxiliary heat output heat pu...

Page 4: ...ack to the temperature setting interface displays and temperature value flashing then press or to modify the value press F or wait for the delay time end return back to normal display Local time can n...

Page 5: ...ps and Heat on disappears from screen Note Aux heat stops and AUX disappears when temp difference is less than 2 2nd heat stops when temp difference is less than 1 Cool Changeover valve keep open Room...

Page 6: ...tting Press to save and enter schedule setting for the following day Under the time setting mode when the time is set to the current schedule will be disabled and it will follow the previous time sett...

Page 7: ...ly back to normal work until the sensor circuit is normal again Z Wave operation Adding Removing of Z Wave network In normal display press hold to enter interface for adding or removing of Z Wave netw...

Page 8: ...es Restoring Factory Settings 1 Remove the device out from Z Wave network can restore factory setting 2 Configure the parameter 10 in secret menu can restore the factory setting also Please use this p...

Page 9: ...ype 1 1H 1C Differential 0 5 1 1 5 2 1 0 2 Temperature calibration 10 10 0 0 3 Temperature setting upper limit 0 37 37 0 Upper limit value lower limit value 4 Temperature setting lower limit 0 37 5 0...