MCO Home MH4 User Manual Download Page 11

 

                                                      www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd   

     

 

11

 

P13 

Heating temp increasing speed  5 

0-99 

 

P14 

Celsius/Fahrenheit 

OC 

OC/OF 

OC

Celsius     

OF

Fahrenheit 

After  modify  settings,  to 

restore the factory settings.

 

 
 
Troubleshooting 
 

Problem 

Solution 

 
Thermostat  functions  but  no  heat 
from the system 

 

1.

 

Check wiring instructions and wire identification 

2.

 

If the GFCI is tripped, reset the thermostat with the side switch 

3.

 

Check  the  resistance  of  the  floor  warming  system.    Refer  to  the  cable 
manufacturer installation manual 

 
No display 

 
Check wiring connection on the back of the unit 

 
GFCI is tripped 

 

1.

 

Check wiring connections 

2.

 

Reset thermostat by switching off then back on 

3.

 

Check  resistance  of  the  floor  warming  system.    Refer  to  the  cable 
manufacturer installation manual 

 
Heat occurs at wrong time 

 
Check the current time and schedule are properly set at AM or PM 

 
Error EEE 

 
Check floor sensor resistance.    Change if out of range 

 

 

               

                                              1-year Limited Warranty                                                 

 

MCOHome  warrants  this  product  to  be  free  from  defects  in  material  and  workmanship  under 

normal and proper use for one year from purchase date of the original purchaser. MCOHome will, at its 
option,  either  repair  or  replace  any  part  of  its  products  that  prove  defective  by  reason  of  improper 
workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO 
THIS  PRODUCT  THAT  RESULTS  FROM  IMPROPER  INSTALLATION,  ACCIDENT,  ABUSE, 
MISUSE,  NATURAL  DISASTER,  INSUFFICIENT  OR  EXCESSIVE  ELECTRICAL  SUPPLY, 
ABNORMAL 

MECHANICAL 

OR 

ENVIRONMENTAL 

CONDITIONS, 

OR 

ANY 

UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not 
apply  if:  (i)  the  product  was  not  used  in  accordance  with  any  accompanying  instructions,  or  (ii)  the 
product was not used for its intended function. This limited warranty also does not apply to any product 
on which the original identification information has been altered, obliterated or removed, that has not 
been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary 
to Country and other applicable export regulations. 

 

 

 

Summary of Contents for MH4

Page 1: ...floor temperature Floor overheating protection GFCI leakage protection level 5mA Multi working modes to meet various user needs Time Period Schedule Mode Comfort Mode Energy saving Mode Vacation Mode...

Page 2: ...be installed indoor a place with around 41 2 to 5 feet height above the floor where represents the average room temperature It should be away from direct sunlight any cover or any heat source to avoi...

Page 3: ...be displayed on the screen OFF In normal working interface slide down the ON OFF button to turn it off It will display OFF on the screen and all outputs will be closed GFCI Test Enter into GFCI test...

Page 4: ...rking interface directly and the values will be saved Working Mode Setting Icon displays on the screen indicates it is in Time Period Mode Icon displays on the screen indicates it is in Manual Mode Ic...

Page 5: ...interface long press button to enter into the Time Period settings interface First the HOUR of the first period is blinking The blinking item is the adaptable item press or button to change the value...

Page 6: ...heating will be turned on and the icon will be displayed on the screen when the detected indoor temperature the set temperature electrical heating will be turned off and the icon will be disappeared...

Page 7: ...Time of the valve In shutdown interface long press button the cumulative time of the valve will be displayed on the screen The cumulative time will reset and restarted when press and buttons simultan...

Page 8: ...TAT_SETPOINT COMMAND_CLASS_THERMOSTAT_MODE COMMAND_CLASS_THERMOSTAT_OPERATING_STAT E COMMAND_CLASS_TIME COMMAND_CLASS_TIME_PARAMETERS Note Basic CC is used to control energy saving mode and comfort mo...

Page 9: ...operate the equipment FCC Interference Statement Part 15 105 b USA only This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC R...

Page 10: ...16 P3 Temperature Backlash Value 2 4 0 5 10 1 18 P4 Key Volume Level 3 OF 1 9 OF OFF 1 9 Length of the Key Volume P5 Backlight Brightness NO NO OF NO Always on OF Energy Saving of Backlight P6 Control...

Page 11: ...e 1 year Limited Warranty MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser MCOHom...

Reviews: