© 2008 McNeilus Truck and Manufacturing, Inc.
Rear Loader
98
3.9
Draining the Leachate Fluid Tank
This procedure describes how to drain the leachate fluid
collection tank. The tank collects waste water at the front of
the body to limit waste water from draining out of the body
or tailgate.
NOTE:
Tank location may vary to fit with chassis
components.
The tank should be drained daily.
1. Perform your company’s Lockout/Tagout procedure.
If your company does not have a Lockout/Tagout
procedure, follow OSHA 1910.147 and 1910.146
Confined Space as appropriate
.
2. Place a drain basin under the valve to collect the
contents of the tank.
3. For tanks with the 4” ball valve, turn the valve lever
clockwise 1/4 turn to open the valve (Figure 55).
Figure 55
4. Drain the tank.
5. Turn the valve lever counterclockwise 1/4 turn to close
Figure 56
6. Dispose of drain basin contents in accordance with
all applicable local, state, or federal waste water
regulations. DO NOT allow the discharge of these
contents to the storm water or any other natural water
resource.
7.
Draining the tank is complete. Remove your company’s
Lockout/Tagout per your company’s procedure. If your
company does not have a Lockout/Tagout procedure,
follow OSHA 1910.147 and 1910.146 Confined Space as
appropriate. Return truck to service.
Preventive Maintenance
Summary of Contents for HD Rear Loader
Page 14: ...This Page Intentionally Left Blank...
Page 52: ...2008 McNeilus Truck and Manufacturing Inc Rear Loader 38 General Information NOTES...
Page 94: ...2008 McNeilus Truck and Manufacturing Inc Rear Loader 80 Operation NOTES...
Page 124: ...2008 McNeilus Truck and Manufacturing Inc Rear Loader 110 Troubleshooting NOTES...
Page 130: ...This Page Intentionally Left Blank...
Page 131: ...This Page Intentionally Left Blank...