36
Black
Power Ground
(GND)
-
Ground @ Device 1
(GND)
Yellow
Data
(TXP)
Output
Data Input @ Device 2
(RXD)
Blue
Data Input –
(RXN)
-
Ground @ Device 2
(GND)
Black
Power Ground
(GND)
-
Ground @ Device 2
(GND)
Figure 9 NMEA0183 to RS232 Connection (Multiplexing)
When wiring NMEA 0183 to AIS-ready equipment, please refer
to your equipment manual first. Smartfind M15 supports three
baud rates: 4800, 9600, and 38400. The default baud rate is
38400. Use the provided McMurdo AIS configuration utility to
change the baud rates (See section 3.8).