Installation manual
Page 1: ...Installation manual ...
Page 2: ...Package Included Bobbie Fasteners Installation template Temperature sensors 1m cable 3x2 5m2 2x brackets Installation stickers ...
Page 3: ...abits and after that you will never have to think about hot water issues You will have hot water whenever you need it Technical characteristics Power Supply 100 240V 50 60Hz IP Protection class IP23 Self consumption 50mA Switching current 32А Wire cross section 1 5 4mm2 Recommended ircuit breaker 50Amax 250V Sensors temperature 0 90оC E meter The controller is designed to using with TN IT distribu...
Page 4: ...r temperature up to 31 С decreasing linearly to 25 relative humidity at temperature 50 С for supply voltage deviation of up to 10 of the declared supply voltage range for use under the overvoltage category II for environment with a degree of contamination 2 PD2 Storage and transport conditions for an ambient temperature 20 С to 60 С for relative humidity 5 to 90 without condensation ...
Page 5: ... with the national electrical installation legislation Safety installation 1 Ensure that the device is attached stable to the wall 2 The device is designed to control active loads with a cos of more than 0 95 3 All works of installation service and repair on the device is only performed when it is securely disconnected from the power supply 4 It is mandatory to disconnect the power supply via a bi...
Page 6: ...on the underside of the device 10 The controller is suitable for use in rooms including bathrooms in places where it is not exposed to the direct impact of splashing water and water jets in areas where the degree of protection IP23 is allowed 11 The cables must be mounted with the plastic fastener bracket provided in the kit 12 Mount the protective plastic cover described in step 12 indicating the...
Page 7: ...upply network with a split between the contacts at all poles ensuring complete disconnection under the overvoltage category III The switch circuit breaker must be built into the fixed wiring in accordance with the electrical regulations The on off button of the controller only serves to functionally shut off the device and can not be regarded as a disconnect from mains supply and only such an instrum...
Page 8: ...elated to the safety of the output and all applicable restrictions the device falls into the following groups overvoltage protection class II type of the chain SELV topology of the network wireless communication Installation of the device shall be carried out in accordance with the manufactur er s instructions in compliance with the requirements of DL 60364 4 41 and national legislation Attention ...
Page 9: ... change without notice MClimate retains all rights to review or update its products software or documentation without being required to notify any natural or legal person The MClimate and MClimate logo are trademarks of Melissa Climate Jsc All other brands and product names mentioned herein are trademarks of their respective owners ...
Page 10: ...g a mains tester switchboard 2 Remove the bottom cover of the water heater Use the water heater installation manual to safely remove the protective cover Ensure that this is allowed by the manufacturer and that you do not violate the warranty of the appliance bipolar switch to shut off the water heater power supply ...
Page 11: ...pe onto the wire with the appropriate symbol The symbols can be found on the terminal to which each wire is connected Once you have tagged the wires you can disconnect them from the terminals 4 Put the pattern on the wall Place the template on the designated mounting location to mark the drilling points on the wall L N Use a mains tester to make sure that there is no voltage in the supply wires ...
Page 12: ...wall Use the fasteners and make sure the device is stably attached to the wall 6 Mount the wires you have marked in step 3 Connect wire L to the terminal Lin wire N to terminal N and ware marked with terminal G N Lout Lin G N Lout Lin G ...
Page 13: ...e wire to terminal N and yellow green to terminal G 8 Mount the additional conductor to the water heater 7 Connect the additional wire L N G N Lout Lin G Make sure that the wires are stable tight to the terminals Only wires with the same cross section must be using Check the maximum water heater current consumption Current consumption up to 16A wire cross section 1 5mm2 Current consumption up to 2...
Page 14: ... Install the water heater protective cover Use the water heater installation manual to reattach the protective cover 10 Connect the Bobbie sensors The sensor cable ends with a connector type RJ Put it in position 5 5 ...
Page 15: ...Insert the cables into the provided grooves in the box and tighten them with the bracket 12 Place the plastic terminal cover over the terminal block Mount the plastic terminal cover with the bolts provided in the set with the symbol on the top ...
Page 16: ...ver Put Bobbie top cover to assemble the device Installation 14 Attach the sensors to the water heater pipes Install the sensors to the hot and cold water pipes The sensors must be attached to a heat conducting metallic part ...
Page 17: ... 15 Turn on the mains power Turn on the mains power from automatic switch in switchboard switchboard Bipolar switch to shut off the water heater power supply Installation ...
Page 18: ...e App You can download the Bobbie mobile app for iOS and Android from www mclimate eu bobbie app Questions For more information about the product and questions related to it visit www mclimate eu Проектирано и създадено от MClimate в България ...
Page 19: ...s in pink the condition switches to constant yellow At this point Bobbie expects a Wi Fi configuration over the mobile application After successfully configuring flashes briefly in light blue and then red Loading Waiting for SmartConfig Connecting to the router Connecting to the server Before making a connection ...
Page 20: ...o pulse suggesting that it is ready for use Pulse in red Water is heating Pulse in Green Bobbie turns off water heater Pulse in Yellow The water heater reached the maximum temperature and the has turned off the load Heating Save energy Maximum energy Once established connection ...
Page 21: ...nk Hard Reset To reset the WiFi settings hold down the button for 10s or until the glow ring is off Toggle Short press without holding the button switches the state of the relay This feature makes it convenient to turn the boiler on or off manually without the need for WiFi connectivity ...
Page 22: ...nts and other applicable provisions of the following EU directives 2014 35 EU Low Voltage Directive BDS EN 60950 1 2014 30 EU EMC Directive BDS EN 301 489 1 v2 1 1 2017 ETSI EN 301 489 1 v2 1 1 2016 BDS EN 301 489 17 v3 1 1 2017 ETSI EN 301 489 1 v3 1 1 2017 Radio Equipment Directive RED 2014 53 EU EN 300 328 V2 1 1 2012 You can find a copy of the Declaration of Conformity at www mclimate eu confor...
Page 23: ...Thank you ...