McIntosh MCLK12 Owner'S Manual Download Page 5

5

Power Control Connector

The MCLK12 Power Control Input receives an On/

Off signal from +5 to +12 volts. The Power Control 

Output will in turn provide a +5 to +12 volts Output 

Signal with a total current up to 

50mA. An additional connec-

tion is for controlling the illu-

mination of Hours and Minutes 

Meters on the MCLK12 along 

with Power Output Meters on 

compatible McIntosh Power Amplifiers. The 1/8 inch 

stereo mini phone plug connects to a McIntosh Pream-

plifier or A/V Control Center Power Control Output.

Note: The Power Control Connecting Cable is available 

from the McIntosh Parts Department:

Data and Power Control Cable Part No. 170-202

Six foot, shielded 2 conductor, with 1/8 inch stereo 

mini phone plugs on each end.

Connector/Cable Information

General Information, Connector/Cable Information, Introduction and Performance Features

Power

Control

Ground

Meter

Illumination

Control

Pass Thru

The McIntosh MCLK12 Analog Clock is a precision 

time piece designed to complement any Audio or Au-

dio/Video System.

Introduction

Performance Features

• Illuminated Meters

The large Minutes and Hour Meters on the MCLK12 

display the current time and are illuminated with extra 

long life Light Emitting Diodes (LEDs)

• Power Control

The Power Control Input and Output connections 

provides convenient Turn-On/Off of Front Panel Il-

lumination of the MCLK12 along with other McIntosh 

Components.

• Precision Oscillator

The MCLK12 circuitry utilizes a precision tempera-

ture compensated quartz crystal oscillator for accurate 

time keeping, even with room temperature fluctua-

tions.

• Lithium Battery

The long life Lithium Battery is used for backup of 

the crystal oscillator for accurate time keeping in the 

event there is an interuption of AC Power.

• Precision Parts

Only the finest precision parts are used throughout.

• Efficient Power Supply

Fully regulated Power Supply ensures stable, accu-

rate time keeping operation even though the power 

line many vary. Its efficient design allow for very low 

energy consumption.

• Fiber Optic Solid State Front Panel Illumination

The even Illumination of the Front Panel is accom-

plished by the combination of custom designed Fiber 

Optic Light Diffusers and extra long life Light Emit-

ting Diodes (LEDs).

• Glass Front Panel

The famous McIntosh Illuminated Glass Front Panel 

ensures the pristine beauty of the MCLK12 will be 

retained for many years.

Summary of Contents for MCLK12

Page 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MCLK12 Analog Clock Owner s Manual...

Page 2: ...d for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularl...

Page 3: ...of having to reset the cor rect time when AC Power is restored The MCLK12 may be supplied with a battery depending on the country where the MCLK12 is purchased When pur chasing a battery for use in t...

Page 4: ...in need of repair you can return it to your Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service D...

Page 5: ...s and Hour Meters on the MCLK12 display the current time and are illuminated with extra long life Light Emitting Diodes LEDs Power Control The Power Control Input and Output connections provides conve...

Page 6: ...ing the best location for your MCLK12 BACKUP BATTERY Front View of the MCLK12 Rear View of the MCLK12 Side View of the MCLK12 17 1 2 44 45cm 8 7 8 22 54cm 16 15 16 43 02cm 7 5 32 18 18cm 7 5 32 18 18c...

Page 7: ...es electronic cables or any heating cooling duct work located in the wall behind where the clock will be mounted 4 Using a drill equipped with a 3 8 inch 9 5 mm drill bit drill two holes into the dryw...

Page 8: ...efer to information on the back panel of your MCLK12 to determine the correct volt age for your unit POWER CONTROL INput receives a turn on signal from a Preamplifier or A V Control Center Removable c...

Page 9: ...ystem may vary from this however the actual components would be connected in a similar manner For additional information refer to Connector and Cable Information on page 5 Power Control Connections 1...

Page 10: ...ours and Minutes Meter indicates the current Hour Front Panel Displays and Controls Meter indicates the current Minute METER LIGHTS switches On Off illumination of the Meters Hours and Minutes also sw...

Page 11: ...rrent time Front Panel Illumination When the MCLK12 is connected to a McIntosh Pre amplifier A V Control Center Integrated Amplifier or A V Receiver via the Power Control Connection the Front Panel Il...

Page 12: ...12...

Page 13: ...13 Photos...

Page 14: ...ower Requirements 100V 50 60Hz at 2 0 Watts 110V 50 60Hz at 2 0 Watts 120V 50 60Hz at 2 0 Watts 220V 50 60Hz at 2 0 Watts 230V 50 60Hz at 2 0 Watts 240V 50 60Hz at 2 0 Watts Note Refer to the rear pan...

Page 15: ...ng carton and interior parts only if they are all in good serviceable condition If a shipping carton or any of the interior part s are needed please call or write Customer Service Depart ment of McInt...

Page 16: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Reviews: