background image

4

Unpacking the MC1502

Caution

To prevent damage to the MC1502 

Vacuum Tubes during shipping, 

there is a special foam insert 

surrounding the Vacuum Tubes of 

the Power Amplifier.

The Foam Insert must be 

removed from the MC1502 

before connecting the AC 

Power Supply Cord to the 

Power Amplifier.

Failure to do so has the 

potential of a Fire Hazard, 

resulting in damage to the 

MC1502 and the surrounding 

environment. 

Follow these instructions for 

removal of the packing foam 

before connecting the AC 

Power Supply Cord to the 

MC1502.

In order to remove the foam insert sur-

rounding the Vacuum Tubes on the MC1502, it 

is necessary to temporarily remove the opera-

tional Tube Shield Metal Cover. After the foam 

insert is removed, the Tube Shield Metal Cover 

is to be re-installed for proper and safe opera-

tion of the MC1502 Power Amplifier. The Tube 

Shield Metal Cover provides protection from 

the hazardous voltages inside the MC1502. The 

MC1502 has no user serviceable parts, includ-

ing the Vacuum Tubes. If repairs are needed 

they must be performed by an authorized Mc-

Intosh Service Agency.

1. Orient the MC1502 so the Front Side of the Power 

Amplifier is facing you and remove the Warning 

Sheet. Refer to figure 1A.

2. Referring to figure 2B (a partial side view of the 

MC1502) to temporarily remove the two screws 

and the Hot Surface Tag located on the top of the 

Tube Shield Metal Cover by using a Phillips Head 

#2 Screw Driver.

3. Carefully lift up and remove the Tube Shield 

Metal Cover from the MC1502. Refer to figure 

3C.

4. Place the Tube Cover and the previously removed 

chassis screws in a safe location, as the Tube 

Cover will be reinstalled.

5. Carefully lift up and remove the Foam Insert from 

the MC1502 exposing the Vacuum Tubes. Refer to 

figures 4D and 5E.

6. Carefully place the previously removed Tube 

Cover on top of the MC1502. Refer to figures 6F 

and 7G.

7. Place the Hot Surface Tag near the top right of the 

Metal Tube Cover. Secure it to the Cover of the 

MC1502 Chassis using the previously removed 

Tube Cover Screws and Retaining Washer. Refer 

to figure 8A and the results of figure 9.

Note: Save the Foam Insert and Warning Sheet with 

the MC1502 Shipping Carton for future use.

Screw 

Figure 2B

Hot Surface Tag

Shipping

Foam

Metal 

Tube 

Cover

POWER 

TRANSFORMER

BLK

BLK/G

RY

GR

Y

VIO

WHT/VI

O

WHT

RE

D

YEL

RE

D

BLU

GRN

BLU

ORN

BL

K

TO

 A

VOID 

FIRE HAZARD, THE FOAM INSERT

 

OVER THE V

ACUUM TUBES MUST BE REMOVED 

PRIOR 

TO

 CONNECTING THE

 A

.C. MAINS POWER 

SUPP

LY

 CORD 

AND OPERA

TING THIS PRODUC

T.

W

ARNING

REFER

 T

O P

AGE 3 IN

 T

HE MC1502 OWNER’S 

MANUAL

 FOR INSTRUCTIONS

.

ON

REMOTE

OFF

ON

OFF

UNITY

 COUPLED 

OUTPUT

 TRANSFORMER

RE

D

BLU

BLK

YE

L

8

+ +

+

4

2

CO

M

VI

O

BR

N

ORN

WHT

WHT

WHT

ORN

BRN

VI

O

V5 // V

7

POWER 150W

V6 // V

8

FREQUENC

Y

15-100kH

z

UNITY

 COUPLED 

OUTPUT

 TRANSFORMER

RED

BLU

BL

K

YE

L

8

+ +

+

4

2

COM

VIO

BRN

ORN

WHT

WHT

WHT

ORN

BR

N

VI

O

V5 // V7

POWER 150W

V6 // V

8

FREQUENCY

15-100kHz

Warning Sheet

Figure 1A

Shipping Foam

Hot Surface Tag

Metal Tube Cover

TO

 A

VOID 

A FIRE HAZARD, THE FOAM INSERT 

OVER THE V

ACUUM TUBES MUST BE REMOVED

 

PRIOR 

TO

 CONNECTING THE 

AC POWER CORD

AND OPERA

TING THIS PRODUCT

.

W

ARNING

REFER 

TO

 T

HE OWNER’

S

MANUAL

 FOR INSTRUCTIONS.

Summary of Contents for MC1502

Page 1: ...McIntosh Laboratory Inc 2 Chambers Street Binghamton New York 13903 2699 Phone 607 723 3512 www mcintoshlabs com MC1502 Power Amplifier Owner s Manual...

Page 2: ...to your Dealer You can also return it to the McIntosh Laboratory Service Department For assistance on factory repair return procedure contact the McIntosh Service Department at McIntosh Laboratory In...

Page 3: ...3 IMPORTANT INSTRUCTIONS FOR REMOVAL OF FOAM INSERT OVER THE VACUUM TUBES PRIOR TO CONNECTING THE A C POWER SUPPLY CORD START ON THE NEXT PAGE...

Page 4: ...Shield Metal Cover from the MC1502 Refer to figure 3C 4 Place the Tube Cover and the previously removed chassis screws in a safe location as the Tube Cover will be reinstalled 5 Carefully lift up and...

Page 5: ...Ventilation Unpacking the MC1502 and Ventilation OFF ON N OF Figure 3C Figure 6F OFF ON N OF Figure 7G Figure 8A Screw Metal Tube Cover Metal Hex Tube Cover Support Hot Surface Tag Washer Figure 9 Hot...

Page 6: ...is enabled For additional information including how to disable it refer to page 13 4 When Power Amplifier Protection Circuitry Sentry Monitor of the MC1502 has activated the Small Vacuum LED Illuminat...

Page 7: ...e for the plates The secondary winding is wound together with the primary windings This provides very close primary to secondary coupling The result is flat frequency response and wide power bandwidth...

Page 8: ...CONTROL INPUT MODE AUTO OFF COM R OUTPUT CLASS 2 WIRING COM L OUTPUT CLASS 2 WIRING MC1502 POWER A MPL IFIER McINTOSH LABORATORY INC BINGHAMTON NY HANDCRAFTED IN USA WITH US AND IMPORTED PARTS BALANC...

Page 9: ...s LEFT OUTPUTS for Class 2 Wiring Connections for a 2 4 or 8 ohm Loudspeakers FUSE HOLDER refer to the nomenclature next to the fuse holder to deter mine the correct fuse size and rating CONNECT the M...

Page 10: ...Power Amplifier Bare wire cable ends Carefully remove sufficient insulation from the cable ends refer to figures 1 2 3 If the cable is stranded carefully twist the strands together as tightly as possi...

Page 11: ...wer impedance connection Refer to General Information Note 6 on page 6 for additional information WARNING Loudspeaker Terminals are hazardous live and present a risk of electric shock For additional i...

Page 12: ...lumination Sentry Protection Circuitry is Activated Right Channel Small Signal Vacuum Tubes LED Illumination Color Operation Mode Function Amber Warm up Audio Signal is muted Green Normal Selected by...

Page 13: ...e to Green The Illumination of Small Signal Vacuum Tubes can also be switched OFF by placing the TUBE LIGHT Control in the OFF position Tube Lights Control The eight Small Signal Vacuum Tubes are Illu...

Page 14: ...0 watts into 2 ohm loads 150 watts into 4 ohm loads 150 watts into 8 ohm loads Output Load Impedance 2 4 or 8 ohms Rated Power Band 20Hz to 20 000Hz Total Harmonic Distortion 0 5 maximum harmonic dist...

Page 15: ...is will ensure the proper equipment location on the bottom foam pad Failure to do this will result in shipping damage To protect the tubes during shippment the Foam Insert removed from the MC1502 need...

Page 16: ...cts is the policy of McIntosh Laboratory Incorporated who reserve the right to improve design without notice Printed in the U S A McIntosh Laboratory Inc 2 Chambers Street Binghamton NY 13903 www mcin...

Reviews: