6
Installation
The MC126 can be placed upright on a table or shelf,
standing on its four feet. It also can be custom installed in a
piece of furniture or cabinet of your choice. The four feet
may be removed from the bottom of the MC126 when it is
custom installed as outlined below. The four feet together
with the mounting screws should be retained for possible
future use if the MC126 is removed from the custom instal-
lation and used free
standing. It also can
be custom installed
in a piece of furni-
ture or cabinet of
your choice The re-
quired panel cutout,
ventilation cutout
and unit dimensions
are shown.
Always provide
adequate ventilation
for your MC126.
Cool operation en-
sures the longest
possible operating
life for any elec-
tronic instrument.
Do not install the
MC126 directly
above a heat gener-
ating component
such as a high pow-
ered amplifier. If all
the components are
installed in a single
cabinet, a quiet run-
ning ventilation fan
can be a definite as-
set in maintaining
all the system com-
ponents at the
coolest possible op-
erating temperature.
A custom cabinet
installation should
provide the follow-
ing minimum spac-
ing dimensions for
cool operation. Al-
low at least 6 inches
Installation
6 -
5/8
"
16.83cm
17-
1/16
"
43.34cm
Cutout Opening for Custom Mounting
MC126 Front Panel
Custom Cabinet Cutout
1-
1/2
"
3.81cm
Cutout
Opening
for
Ventilation
Cutout Opening for Ventilation
Support
Shelf
Cabinet
Front
Panel
Chassis
Spacers
MC126 Side View
in Custom Cabinet
MC126 Bottom View
in Custom Cabinet
9-
1/2
"
24.13cm
14"
35.56cm
13-
3/16
"
33.50cm
14-
1/16
"
35.72cm
6"
15.24cm
(15.24 cm) above the top, 2 inches (3.81cm) below the bot-
tom and 1 inch (2.54 cm) on each side of the amplifier, so
that airflow is not obstructed. Allow 20 inches (50.8 cm)
depth behind the front panel. Allow 1 inch (2.54 cm) in
front of the mounting panel for knob clearance. Be sure to
cut out a ventilation hole in the mounting shelf according
to the dimensions in the drawing.