background image

MONO LOAD 

OHMS VOLTS 

2 44.7 
4 63.2 
8 89.4 

16 126.5 

MONO BRIDGE OPERATION 

CONNECT LOW 

SIDE OF LOAD 

TO TERMINALS 

L1

L2

L4

L8

CONNECT HIGH 

SIDE OF LOAD 

TO TERMINALS 

R 1

R2

R4

R8

IN BRIDGE OPERATION THE OUTPUT IS BALANCED TO 

GROUND AND NEITHER OUTPUT LEAD IS AT GROUND 

POTENTIAL 

MONO PARALLEL OPERATION 

CONNECT LOW 

SIDE OF LOAD TO 

MONO LOAD BOTH TERMINALS 

OHMS VOLTS 

1

/

2

 22.4 L COM & R COM 

1 31.6  L C O M & R C O M 

2 44.7 L COM & R COM 
4 63.2 L COM & R COM 

CONNECT HIGH 

SIDE OF LOAD TO 

BOTH TERMINALS 

L1

W

 & R 1

L 2

W

 & R 2

L 4

W

 & R 4

L 8

W

 & R 8

DO NOT OPERATE AMPLIFIER WITH MODE SWITCH IN THE 
STEREO OR MONO BRIDGE POSITION WITH THE OUTPUTS 

PARALLELED AS ABOVE 

Figure 3 

Figure 4 

Monophonic operation: 

When the MC 2500 is used as a monophonic or 

single channel power amplifier the two channels are 
combined to produce an output power of 1000 watts. 

The left and right outputs must be tied together at 

the appropriate load impedance taps. Figure 3 
shows the connections for MONO BRIDGE opera-
tion and Figure 4 shows the connections for MONO 

PARALLEL operation. 

Make all speaker connections at the amplifier on-

ly. For multiple speaker operation, parallel the leads 

from the speakers to the amplifier. 

AC POWER 

The MC 2500 is designed to operate on 120 volts 

50/60 Hz. Plug the AC power cord directly into a wall 
outlet. Make certain that the AC power outlet has at 

least 15 ampere capacity with nothing else connec-

ted to the circuit. Do not plug the MC 2500 into an 
auxiliary AC power outlet on a preamplifier or other 

source equipment unless it is known there is ade-

quate current capacity. If remote power operation is 

required, an external relay arrangement must be 
made. If an extension cord is used make certain that 

it has 15 ampere current capacity. 

The MC 2500 draws 15 amperes AC line current 

when amplifying music or speech at rated output on 

program peaks. The amplifier uses only 0.7 ampere 

while idling at no output. If the amplifier is driven to 

rated output using sine wave signals it will draw 22 
amperes. The MC 2500 is designed for continuous 

and reliable operation at any power level to its rated 
500 watts continuous average power output per 
channel or 1000 watts as a mono amplifier. For con-

tinuous sine wave operation the AC source must be 
capable of supplying the required 22 amperes. 

-4-

Summary of Contents for MC 2500

Page 1: ...Price 2 00 Reading Time 32 Minutes THE MclNTOSH MC 2500 STEREO POWER AMPLIFIER...

Page 2: ...aced on can support the weight 5 The amplifier cooling fans can be thermostatically controlled when the fan switch on the rear panel is placed in the thermally switched positions When so operated the...

Page 3: ...rvice done by a Mclntosh authorized service agency If the instrument is modified or damaged as a result of unauthorized repair the SERVICE CONTRACT will be cancelled Damage by improper use or mishandl...

Page 4: ...y high operating tempera tures The direct benefit of adequate ventilation is longer trouble free life The heat generated in the operation of the MC 2500 is exhausted from the unit by two temperature c...

Page 5: ...tereo operation STEREO LOAD OHMS VOLTS 1 22 4 2 31 6 4 44 7 8 63 2 STEREO OPERATION CONNECT LOW SIDE OF LOADS TO TERMINALS LEFT COM COM COM COM RIGHT COM COM COM COM CONNECT HIGH SIDE OF LOADS TO TERM...

Page 6: ...ation Make all speaker connections at the amplifier on ly For multiple speaker operation parallel the leads from the speakers to the amplifier AC POWER The MC 2500 is designed to operate on 120 volts...

Page 7: ...Stereophonic Connections 5...

Page 8: ...Mono Bridge Connections 6...

Page 9: ...Mono Parallel Connections 7...

Page 10: ...h channel Ordinary meters lack the capability of indi cating the short interval information in a sound wave The mass of the meter movement is too great to respond to the nearly instantaneous changes i...

Page 11: ...fier output clipping is eliminated Clipping is caused when an amplifier is asked to produce more power output than it can de liver with low distortion Amplifiers are capable of delivering large quanti...

Page 12: ...operate in three modes Stereo Mono Bridge and Mono Parallel The Mono modes differ in the loads they will drive and the connection sequence to the speaker terminals A connection chart appears on the re...

Page 13: ...ns will continue to operate When the amplifier has cooled it will automatically turn on again AC POWER The MC 2500 is designed to operate on 120 volts 50 60 Hz The amplifier draws 15 amperes line cur...

Page 14: ...er side is grounded RATED POWER BAND 20 Hz to 20 000 Hz TOTAL HARMONIC DISTORTION STEREO 0 02 maximum harmonic distortion at any power level from 250 milliwatts to 500 watts per channel from 20 Hz to...

Page 15: ...Performance Charts 13...

Page 16: ...14...

Page 17: ...e differential pair is adjustable Cor rect adjustment allows the lowest possible distor tion at low frequencies A current mirror circuit com bines the differential outputs into one signal which is the...

Page 18: ...cted sili con diode pair as feedback elements These diodes have a uniform logarithmic characteristic over an 80 dB range Only 60 dB of this logarithmic range is us ed in the MC 2500 The full wave rect...

Page 19: ......

Page 20: ...2 CHAMBERS ST BINGHAMTON N Y 13903 9990 607 723 3512 The continuous improvement of its products is the policy of Mclntosh Laboratory Incorporated who reserve the right to improve design without notice...

Reviews: