MCH M3000i Manual Download Page 1

  generator  is  designed  to  give  safe  and  dependable  service  if 

operated  according  to  instructions.  Read  and  understand  the  Owner’s 
Manual  before  operating  the  generator.  Failure  to  do  so  could  result  in 
personal injury or equipment damage.

• The illustration may vary according to the type. 

-1-

PREFACE

Thank you for purchasing 

 generator.

This manual covers operation and maintenance of the 

3000i

 generator.

All information in this publication is based on the  latest product information 
available at the time of approval for printing.

reserves the  right to make  changes at  any time without notice 

and without incurring any obligation.
No  part  of  this  publication  may  be  reproduced  without  written permission.
This manual should be considered a permanent part of the generator and 
should remain with it if it is resold.
Pay special attention to statements preceded by the following words:

 

        

Indicates a strong possibility of severe personal injury or death if 

instructions are not followed.
CAUTION: Indicates a possibility of personal injury or equipment damage 
if instructions are not followed.
NOTE: Gives helpful information.
If a problem should arise, or if you have any questions about the 
generator, consult an authorized 

 dealer.

WARNING

MCH

M

MCH

MCH

MCH

Summary of Contents for M3000i

Page 1: ...ting reserves the right to make changes at any time without notice and without incurring any obligation No part of this publication may be reproduced without written permission This manual should be c...

Page 2: ...ACAPPLICATIONS 18 AC PARALLEL OPERATION 18 AC Parallel Opertion Applications 19 DC OPERATION 20 SMART THROTTLE SYSTEM 21 STANDBY POWER 21 Connections ToABuilding s Electrical System 21 System Ground 2...

Page 3: ...Cleaning 32 The Fuel Tank And Carburetor 33 Engine Oil 34 STORAGE PRECAUTIONS 34 REMOVAL FROM STORAGE 34 TRANSPORTING 35 TAKING CARE OF UNEXPECTED PROBLEMS 36 37 ENGINE WILL NOT START 36 APPLIANCE DOE...

Page 4: ...n case of emergency Understand the use of all generator controls output receptacles and connections Be sure that anyone who operates the generator receives proper instruction Do not let children opera...

Page 5: ...unprotected from the weather check all of the electrical components on the control panel before each use Moisture or ice can cause a malfunction or short circuit in electrical components that could re...

Page 6: ...rks away Always store gasoline in an approved container Make sure that any spilled fuel has been wiped up before starting the engine Explosion proof This generator is not compliant with explosion proo...

Page 7: ...ntact your servicing dealer for a replacement GENERATOR SAFETY 7 SERVICE DETAILS EVERY 3 Months or 50 Hours EVERY 6 Months or 100 Hours Spark plug MUST be cleaned or replaced Replacoment oll SAE 10W 3...

Page 8: ...ity company workers or others who contact the lines during a power outage and the generator may explode burn or cause fires when utility power is restored Consult the utility company or a qualified el...

Page 9: ...equently used controls 9 OVERLOAD INDICATOR OUTPUT INDICATOR OIL ALERT INDICATOR DC RECEPTACLE Cigarette Lighter Socket DC CIRCUIT PROTECTOR ENGINE SWITCH AC CIRCUIT PROTECTOR SMART THROTTLE SWITCH GR...

Page 10: ...AIR CLEANER COVER AIR CLEANER SPARK PLUG MAINTENANCE COVER SPARK PLUG AIR CLEANER COVER SCREW CONTROLS FEATURES 10 The engine switch controls the ignition system fuel valve and choke valve OFF Stops t...

Page 11: ...witch e h t n r u t t u p t u o C D e h t g n i s u n e h W s e g n a h c e g a t l o v e c u d e r o t n o i t i s o p F F O e h t o t Smart throttle switch to the OFF position ON Recommended to mini...

Page 12: ...ands To fold the handle Lower the handle with both hands until it clicks into place FOLDING HANDLE NOTICE CORRECT FEATURES Ground terminal Be sure to ground the generator when the connected equipment...

Page 13: ...aded in excess of 3 0 KVA or if there is a short circuit in a connected appliance the overload indicator red will come on If the overload indicator red stays on continuously for more than 3 seconds cu...

Page 14: ...your risk of injury Know ledge Read and understand this manual Know what the controls do and how to operate them Familiarize yourself with the generator and its operation before you begin using it Kno...

Page 15: ...C appliance or power cord to the generator Use grounded 3 prong extension cords tools and appliances or double insulated tools and appliances Inspect cords and plugs and replace if damaged Make sure t...

Page 16: ...ke sure the Smart throttle switch is in the OFFposition 3 Turn the engine switch to the ON position To start a cold engine turn the engine switch to the CHOKE position To restart a warm engine leave t...

Page 17: ...g for startup When an electric motor is started the overload indicator red may come on This is normal if the overload indicator red goes off within 9 seconds If the overload indicator red stays on con...

Page 18: ...ntinuous operation do not exceed the rated power Rated power is 2 6KVA The total power requirements KVA of all appliances connected must be considered AC applications NOTICE NOTICE AC parallel operati...

Page 19: ...Before connecting an appliance or power cord to the generator Make sure that it is in good working order A faulty appliance or power cord can create a potential for electrical shock If an appliance be...

Page 20: ...while the AC power is in use When using the AC power together with DC power do not exceed 20 8 ampere AC load When using the DC output turn the Smart throttle switch to the OFF position Connecting the...

Page 21: ...ngine returns to the proper speed to power the electrical load In the OFF position the smart throttle system does not operate Appliances with large start up power demands may not allow the engine to r...

Page 22: ...c Cooling holes are located on the front panel rear panel and the bottom of the generator If the cooling holes are blocked the generator may overheat and damage the engine inverter or windings Do not...

Page 23: ...cing dealer for recommend ations applicable to your individual needs and use WARNING Improper maintenance or failure to correct a problem before operation can cause amalfunction in which you can be se...

Page 24: ...ssibility of fire or explosion be careful when working around gasoline Use only a non flammable solvent not gasoline to clean parts Keep cigarettes sparks and flames away from all fuel related parts M...

Page 25: ...le fuel only outdoors Wipe up spills immediately Fuel can damage paint and plastic Be careful not to spill fuel when filling your fuel tank Damage caused by spilled fuel is not covered under warranty...

Page 26: ...roblems that result from using a fuel with percentages of ethanol or methanol greater than shown above are not covered under warranty If your equipment will be used on an infrequent basis please refer...

Page 27: ...ine switch to the OFF position to reduce the possibility of fuel leakage 2 Place wood blocks 3 5 in 90 mm or greater under the generator as shown wood blocks 3 Remove the engine oil maintenance cover...

Page 28: ...ard it in a trash bin dump it on the ground or pour it down the drain 9 With the generator in a level position fill with the recommended oil see page 29 to the upper limit of the oil filler neck 10 Re...

Page 29: ...mperature in your area is within the recommended range AMBIENT TEMPERATURE Air cleaner service 1 Loosen the air cleaner cover screw and remove the air cleaner cover 5 Reinstall the air cleaner cover a...

Page 30: ...if too much oil is left in the air filters 3 Wipe dirt from the air cleaner case and cover using a moist rag Be careful to prevent dirt from entering the air duct that leads to the carburetor Spark p...

Page 31: ...Overtightening the spark plug can damage the threads in the cylinder head 9 Reinstall the spark plug cap on the spark plug securely 10 Reinstall the spark plug maintenance cover NOTICE SEALING WASHER...

Page 32: ...with your servicing dealer for local storage recommendations Gasoline will oxidize and deteriorate in storage Old gasoline will cause hard starting and it leaves gum deposits that clog the fuel system...

Page 33: ...the tank Do not use an electric pump Reinstall the debris screen and the fuel tank cap 2 Loosen the cover screw and remove the air cleaner cover see page 29 3 Place a suitable container under the drai...

Page 34: ...ny area with a spark producing electric motor or where power tools are operated If possible avoid storage areas with high humidity because that promotes rust and corrosion Unless all fuel has been dra...

Page 35: ...can ignite some material To prevent fuel spillage when transporting the generator should be secured upright in its normal operating position with the engine switch OFF Take care not to drop or strike...

Page 36: ...an authorized dealer Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical appliance...

Page 37: ...dealer No electricity at the DC receptacle Technical consumer information YES NO Is the DC circuit protector ON Record the frame serial number and date purchased in the spaces below You will need thi...

Page 38: ...odification This engine when operated at high altitude with the carburetor modifications for high altitude use will meet each emission standard throughout its useful life Even with carburetor modifica...

Page 39: ...e Stroke 12 7 cu in 208 cm3 2 75 2 13 in 70 0 54 0 mm Compression ratio 8 5 1 Engine speed 3400rpm Cooling system Forced air Ignition system Full transistor Oil capacity 0 53 lmp qt 0 6 L Fuel tank ca...