Operation - Socket Fuse to Outlet
Hornet™ XL
If the heater is not operating properly, the control will attempt
to turn the heater off and the red indicator light will flash
rapidly. If this occurs, disconnect the power and take it to a
McElroy Authorized Service Center for repair.
5)
Allow heater to warm-up to operating temperature.
Mark Insertion Depth
1)
Use a marking instrument and mark the insertion depth
according to the appropriate joining standard. The
mark can be made using the insertion depth gauge.
This mark is the insertion depth used when fusing the
pipe and fitting.
The chamfer/depth gauge tool may be used to
chamfer the end of the pipe as well as determine the
insertion depth. Mark the insertion depth along the
edge of the chamfer/depth gauge. The chamfer/depth
gauge is pipe size specific.
Clean Fitting and Pipe
1)
Fitting and pipe must be clean and dry. Use a clean lint
free cloth to wipe the mating surfaces.
NOTICE:
Do not touch fusion area with hands.
Load Pipe
1)
Ensure the Acrobat™ pipe inserts are installed for the
size of pipe to be fused.
2)
Load the pipe into the jaws of the carriage. Allow
enough pipe to protrude so that the pipe can be
inserted to the insertion depth. Tighten the clamp knobs
on the carriage.
NOTICE:
Overtightening the jaws could distort the pipe or
fitting resulting in a questionable fusion joint.
5)
Open the carriage completely to allow the heater to be
inserted.