background image

 

 

 
 

 

 

Instruction Sheet: 

43800101

 

4

 

 

2"- 4" Heater Rebuild Kits 

A227001, A227002, A438001, A438002

06/16/21    REV. C

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PH02752-12-04

Step 4 

Put the cartridge heaters and RTD through the slot in the 
gasket.  Align the handle with the body so that the 
thermometer holes in the body, gasket and handle line up.  
Slide the heater cartridges into the outer holes and the RTD 
into the drilled hole in the body.  Make sure the cartridges 
are all the way in, at least flush with the bottom of the body 
recess.   

TX02043-07-16-02 

 

 

 
 

 

Step 5 

Clean area around the screw hole to ensure good electrical 
connection. 
Attach the ground wire to the heater body with the #6-32 
screw. 

 
 
 
 
 
 
 

 
Step 6 

Put the handle on the top of the body while pushing the RTD 
as deep as it will go down in its hole.  The wires to the 
cartridge heaters will fold into the recess.  Loosely bolt on 
the new handle/controller assy with the thermometer guard 
and stripper bar using the (2) 1/4-20 socket head 
capscrews.  If available, apply high temperature anti-seize 
compound (not included in the kit) to the screw threads.  
Install the thermometer and then tighten the two socket 
head capscrews using a 3/16” hex wrench. 

TX02044-07-16-02 

 
 
 

 
 

Step 7 

Several Part Number Labels may be included in the kit.  
Choose the one that matches the heater size, voltage and 
configuration.  Affix it to the back of the handle.  Be sure it is 
turned the same way as the MMI logo on the handle.  
Discard the remaining Part Number labels. 

TX02045-07-16-02

 

 
 
 

PH02754-12-04

PH02753-12-04

Reviews: