8.7.
Resetting
Pushing the button on the front panel for about 10 seconds resets the USB hub to factory settings. The hub
then restarts. The ports and multiplexers will be switched accordingly. This must be followed by the
corresponding command. If the button lock is active, this function is not possible. The factory settings
include:
Normal mode after power on
No exceptions for ready mode
After ready mode, restore the state from before ready mode
All USB ports are standard ports (SDP)
Current limitation of all ports is 2.5A
Connection detection for USB devices is enabled
The button is unlocked.
All USB ports are off after the USB hub is turned on
All relay multiplexers are on after the USB hub is turned on
The recognition number is not changed
All USB ports are turned off by a reset. Disconnect all connected storage media from the operating
system beforehand.