14 | ENGLISH
Unit fails to heat up.
Steam output is weak or
intermittent.
Excessive amount of water in
steam.
NOTE: Unit produces wet steam
– it is normal for steam to
contain some amount of water.
Unit is not plugged in. Household
circuit breaker / ground fault inter-
rupter has tripped or blown a fuse.
Mineral build-up in unit.
Mineral build-up in unit.
Unit is damaged or otherwise in
need of repair.
Water level in Boiler is running
low.
Boiler is empty.
Water condensation in Extension
Hose.
Boiler has been
overfilled.
Plug power cord into electrical outlet.
Refer to
Mineral Build-up
section
on Page 13 for cleaning procedure.
Refer to
Mineral Build-up
section
on Page 13 for cleaning procedure.
Reset circuit breaker / ground
fault interrupter, or replace fuse.
If you need assistance, contact a
licensed electrician.
Immediately cease usage and
unplug. Contact Consumer
Service for further assistance
(see Page 16 for details).
Refer to
Filling The Boiler
proce-
dure on Page 11.
Refer to
Filling The Boiler
proce-
dure on Page 11.
Point nozzle towards sink, tub or
ground and shake while pressing
Steam Trigger. Continue until
excess water is released.
Filling Boiler with more than 6 oz.
(177 ml.) of water interferes with
steam production, resulting in
water condensation in steam.
Always use included Fill Cup to fill
unit with correct amount of water.
(see Page 11 for details)
PROBLEM
POSSIBLE CAUSE
SOLUTION
Accessories do not stay firmly
connected to Steam Nozzle.
Accessories not properly installed. Check to make sure that acces-
sories are properly connected, per
procedures on Pages 8-9.
Troubleshooting