McAfee® Network Security Platform 6.0
System Fault Messages
53
Fault
Severity
Description/Cause
Action
The Manager
<Manager name>
is not reachable
Critical
No communication exists
between Central Manager and
Manager.
Indicates that the Central
Manager server and Manager
cannot communicate with
each other. The connection
between these two may be
down, or Central Manager has
been administratively
disconnected.
1) Check that a connection
route exists between the
Central Manager and
Manager;
2) Access the Manager
directly. This fault clears when
the Manager detects the
Sensor again.
The Manager
name has moved
to MDR mode, and
this Manager
cannot handle the
change
Critical
The Central Manager server is in
Standby mode.The Manager
server which is configured by
Central Manager goes into
secondary Standby mode after
MDR creation or before data
dump from primary to secondary
takes place.
The Manager server configured
by Central Manager is in Active
mode but is in a disconnected
state and therefore cannot
communicate with Central
Manager.
If Manager is reconnected and
Central Manager is in Standby
mode, then the Peer Central
Manager does not have
Manager configuration.
If the Central Manager server
has moved to Standby ,then
the Central Manager with
latest Manager information is
moved to Active mode or
recreate MDR pair.
If the Manager has moved to
Standby, then make the
Manager with Central
Manager information as Active
or make sure that active
Central Manager or Manager
has latest configuration data.
The Manager has
moved to MDR
mode, and this
Manager cannot
handle the change
Critical
The Manager server is in
Standby mode(MDR action) and
active peer Manager does not
have Central Manager
information
If the Manager server has
moved to Stand by ,then make
Central Manager with latest
Manager information as Active
or reform MDR; if the Manager
has moved to Standby, then
make the Manager with
Central Manager information
as Active or make sure that
active Central Manager or
Manager has latest
configuration data.