![MC Electronic SAFETY-FLY 700 P User Manual Download Page 9](http://html1.mh-extra.com/html/mc-electronic/safety-fly-700-p/safety-fly-700-p_user-manual_1753058009.webp)
9
1.6 Electrical connections
Set the connections up as shown in the table, observing the colours of the cables, and
referring to the STC 1017.1 connection board on page 24-25
8-POLE Input/Output CONNECTOR
8-pole connector wire colours
Description of connections
Orange
Input (-) cylinder head temperature CHT
Black
Input (-) Motor oil temperature
Red
Input (-) motor pressure temperature
Green
Input (-) Flaps sensor
Yellow
Input (+) fuel pressure transducer
Grey
Input R,
to be brought up to +12V when the fuel transducer
is not connected to the fuel pressure instrument.
Brown
Buzzer output (-)
Blue
Buzzer output (+)