It  is  recommended  that  at  the  end  of  each  day,  paint

should  be  flushed  from  unit  with  compatible  solvent  then

reflushed with mineral spirits.

1.-

2.-

3.-

4.-

5.-

Engage  the  gun  safety  and  follow  the  Pressure

Relief  Procedure.

Remove the spray tip and clean with a compatible

solvent and soft brush.

Disengage the gun safety and follow the pressure

relief  procedure. Lift suction tube above paint level

until tube is  empty.

Introducing the suction tube in a pail with compatible

solvent. Disengage gun safety and trigger gun into

the pail until it runs clear. Close the air inlet valve.

Open the fluid drain valve. Remove the fluid filter

and the gun filter and clean them with solvent.

Flush the sprayer at the end of each work day and

fill it with solvent to help prevent pump corrosion.

4

SPRAY TIPS

When a tip is the wrong size, or becomes the wrong size

through wear, the spray pattern worsens, coverage decreases,

you have less control over the desired  rate of coverage, and it

takes  longer  to  finish  the  job.  In  the  worst  case,  the  pump

supplying the tip can be damaged. Because most architectural

coating are abrasive, tip wear can happend quite quickly. Notice

as wear increases the orifice size, it decreases the fan width

which greatly affects coverage rates.

If  tip  shows  excessive  wear,  replace  it  to  maximize

productivity and save paint.

PARTS LIST

1.-

2.-

3.-

4.-

5.-

6.-

7.-

8.-

9.-

10.-

11.-

12.-

AIR MOTOR

DISPLACEMENT PUMP

AIR LINE FILTER AND AIR REGULATOR

FLUID SUCCION LINE

FLUID DRAINVALVE

AIR INLET VALVE

FLUID FILTER

PACKING NUT

FLUID HOSE

GUN

SAFETY KNOB

GROUND  CONNECTION

Summary of Contents for TEL 30BS

Page 1: ...UCTIONTHATMUST BE READ BEFORE OPERATING THE PUMP INSTRUCTIONS AND PARTS LIST SPRAY EQUIPMENT MBPS L C Anboto 17 Poligono ANSOLETA Phone 34 945 132744 Fax 34 945 134756 01006 VITORIA Alava SPAIN P O BO...

Page 2: ...e If every part of spray equipment is not properly grounded sparking immediately Check the entire system for positive grounding GROUNDING Before starting to work the pump must be connected to ground I...

Page 3: ...he gun before the fluid being sprayed can dry in it Engage the gun safety latch Shut off the air to the pump Close the air inlet valve Disengage the gun safety latch Hold a metal part of the gun firmi...

Page 4: ...lter and clean them with solvent Flush the sprayer at the end of each work day and fill it with solvent to help prevent pump corrosion 4 SPRAYTIPS When a tip is the wrong size or becomes the wrong siz...

Page 5: ...100 MESH FILTER 200 MESH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 19 20 21 22 25 26 27 28 29 30 31 32 33 34 G 100 XX C PA1 01 C 200 01X B 120 00X B 130 01X B 130 02 B 130 03X C TU1 01 B 110 00X B 100...

Page 6: ...TAINER GROUND 1 1 1 2 1 1 1 2 2 1 2 1 1 1 1 1 2 1 6 16 2 2 2 2 4 1 2 2 1 1 N REF DESCRIPCION Q A 110 02 CJT 001 A 210 01 A 120 04 A 220 07 A 120 08 A 221 00 CTJ 002 A 240 02 A 240 01 A 122 00 CJT 005...

Page 7: ...100 150 200 250 300 350 100 150 200 250 300 350 100 150 200 250 300 350 009 9 20 9 40 9 60 011 11 20 11 40 11 60 013 13 20 13 40 13 60 015 15 20 15 40 15 60 017 17 20 17 40 17 60 019 19 20 19 40 19 60...

Page 8: ...urer M B P will provide purchaser with reasonable assistance in making such claims The Industry Department of The Basque Goverment states that all electric and pneumatic airless equipment manufacture...

Reviews: