3.4 Programming the Model 46

Switch on the power. Select ”Mode” and press the OK button. Choose ”On-line” if the
Model 46 is used together with a collator Model 306/310 and/or a mailer/inserter Model
45. Choose ”Stand Alone” to use the Model 46 as a stand alone booklet feeder. If the
Model 46 should be inactivated choose ”Off-line”. Confirm your choice by pressing the OK
button.

Select ”Sheets per set” and press the OK button. Enter number of sheets per set using the
arrow buttons. The range is 1 to 45 sheets per set. Default value is 1. Confirm by pressing
the OK button.

Select ”Length” and press the OK button. Enter the length of the inserts (in the feed direc-
tion) using the arrow buttons. The range is 100 to 310 mm. Default value is 200 mm. Con-
firm by pressing the OK button.

Select ”Sets per hour” and press the OK button. Enter the number of sets per hour using
the arrow buttons.  The range is 1000 to 3600 sets per hour. Default value is 1800. The
speed will however be limited to match units attached. Confirm by pressing the OK button.

Select ”Belt speed” and press the OK button. Enter a percentage using the arrow buttons.
The range is 60 to 100%. Default value is 80%. Confirm by pressing the OK button.

Select “Placement”. If necessary, change the feeding order (ID number) by pressing the OK
buttton. Lowest number feeds first and so on. Leave the “Placement” option menu using the
ESC button.

If you wish to reset the set counter select ”Clear counter” and press the OK button. The next
menu shows the actual value of the set counter. Clear the set counter by pressing the OK
button.

If you wish to program a specific number sets for a job, select ”Preset counter” and press
the OK button. The next menu shows the actual value of the preset counter and how many
more sets to go to finish the job. Enter a new value using the arrow buttons.
Default value is 0. Confirm by pressing the OK button.

Booklet Feeder Model 46 Operator Manual

3-4

After setting up attached units according to their respective operator instructions, the sys-
tem is ready to be started. The system can be started and stopped using the start and stop
buttons on any unit in the system.

3.5 Start inserting

Summary of Contents for Model 46

Page 1: ...Booklet Feeder Model 46 Operator Manual Dec 2000 Part No 45993...

Page 2: ...chart 2 2 2 3 How to read the display 2 3 2 4 Explanation of the menus 2 3 3 Operator instructions 3 1 Setting up the Model 46 3 1 3 2 Adjusting the separation 3 2 3 3 Loading 3 3 3 4 Programming the...

Page 3: ...ys keep magnets and all devices with strong magnetic field away from the machine Never use a ground adapter plug to connect the equipment to a power source receptacle that lacks a ground connection te...

Page 4: ...in components 1 Insert side guides 2 Insert front guide 3 Separator pads adjustment knob 4 Outfeed sensor 5 Docking plate 6 Insert rear guide adjustment knob 7 Insert rear guide 8 Control panel 9 Inse...

Page 5: ...SE PAUSE ADJUST On Line Off Line Off Line Stand Alone Sheets Set 1 L 210mm BS 70 Clear Counter 00075 Counter 00100 Remaining 00025 Sheets Set 1 Length 210mm SPH 2800 BS 70 Run Diagnosis STOP 00075 CON...

Page 6: ...n the Model 46 is switched on The information in the display shows that the Model 46 is ready to start it is in this case on line with the system and the ID number in the system is one See table below...

Page 7: ...n menu there are three options SETS PER HOUR CLEAR COUNTER and PRESET COUN TER Scroll select option with the arrow buttons and confirm with the OK button SETS PER HOUR Change the number of sets per ho...

Page 8: ...es or the ESC button to cancel In either case you will be returned to the Option Menu s Decide whether the Model 46 should be on line or off line with the system or function as a stand alone unit This...

Page 9: ...e it can create interruption Belt speed is how fast each insert will be fed Enter a per centage using the arrow buttons The range is 60 to 100 Default value is 80 If the belt speed is too slow the ins...

Page 10: ...collator adjust the paper deflector so that the leading edge of the sheets lands between the insert feed belts on the Model 45 document table To exclude the Model 46 from the system just select Off l...

Page 11: ...ment knob until the feed belts moves when the booklet is pulled back and forth Booklets up to 3 mm thickness Place the booklet between the separator pads and the feed belt as shown in the figure Tight...

Page 12: ...be shown in the display Move the rear guide to the right to increase the friction Adjusting the rear guide too much to the right may cause the next insert to follow directly after the first one The er...

Page 13: ...ed to match units attached Confirm by pressing the OK button Select Belt speed and press the OK button Enter a percentage using the arrow buttons The range is 60 to 100 Default value is 80 Confirm by...

Page 14: ...ing the test the display will show which part that currently is tested After the test you can scroll with the arrow buttons to check that all parts diagnosed passed the test If all parts checked not p...

Page 15: ...A 2 t s u d h t i w d e t a n i m a t n o c e b y a m r o s n e S 3 n u R r o s n e s d e e f t u o e h t n a e l c k c e h C e h t f I r o s n e s f o s u t a t s y f i r e v o t s i s o n g a i D e...

Page 16: ...o i t p u r r e t n I 2 s i t a h t t i n u h c i h w y f i t n e d i o t 4 2 n o i t c e s e e S m e l b o r p e h t g n i s u a c e r a t o n s e h c t i w s k c o l r e t n i e h t t a h t k c e h...

Page 17: ...in 140 x 210 mm Max 310 x 310 mm Paper weight Min 60 gsm Max Speed Up to 3600 sets per hour Max packing thickness 8 mm Misfeed detection Yes Jam detection Yes Height 1020 mm Width 510 mm Depth 480 mm...

Reviews: