BLAST CHILLERS AND FREEZERS
USER MANUAL n° 6CE648137NU
–0818
Page 3
Model:
A5A20
Refrigerant:
R290
Cooling
Freezing
G.W.P. :
3
Type:
Integral
Capacity (Kg) :
0,12
Capacity :
kg
20
10
Temperature of start of cycle :
o
C
65
65
Temperature of end of cycle :
o
C
10
-18
Time of the cycle :
min.
90
270
Energy
consumption:
kWh / kg
0,031
0,049
Model:
A5A20
Refrigerant:
R404A
Cooling
Freezing
G.W.P. :
3922
Type:
Integral
Capacity (Kg) :
0,45
Capacity :
kg
20
10
Temperature of start of cycle :
o
C
65
65
Temperature of end of cycle :
o
C
10
-18
Time of the cycle :
min.
90
270
Energy
consumption:
kWh / kg
0,046
0,070
Model:
A5A20 S/G
Refrigerant:
R404A
Cooling
Freezing
G.W.P. :
3922
Type:
Remote
Capacity (Kg) :
n/a
Capacity :
kg
20
10
Temperature of start of cycle :
o
C
65
65
Temperature of end of cycle :
o
C
10
-18
Time of the cycle :
min.
90
270
Energy
consumption:
kWh / kg
0,003
0,007