![mbj CTR-52 Operating Instructions Download Page 2](http://html.mh-extra.com/html/mbj/ctr-52/ctr-52_operating-instructions_1752578002.webp)
24V DC
24V DC
20 mA
Trigger LED 1
from Camera/ PLC
PC or PLC
Modbus Server
Trigger
GND
24V DC
20 mA
24V DC
20 mA
24V DC
20 mA
Trigger LED 2
from Camera/ PLC
Trigger LED 3
from Camera/ PLC
Trigger LED 4
from Camera/ PLC
CTR-52
Modbus Slave
1 Tr.1
2 Tr.2
3 Tri.3
4 Tri.4
5 Tri GND
6
7
LED 1 (+)
LED 1 (-)
LED 2 (+)
LED 2 (-)
LED 3 (+)
LED 3 (-)
LED 4 (+)
LED 4 (-)
1k2
1k2
1k2
1k2
LED
Driver
LED
Driver
LED
Driver
LED
Driver
Specification
CTR-52
Electrical parameter
Operating Voltage
24V DC / 4A
12V - 26V, min. 2V above the forward voltage of
the LED light source
LED steady current
1)
(ON & AUTO mode)
1 Channel: 1800mA
2 Channels: 1500mA p. Channel
3 Channels: 1200mA p. Channel
4 Channels: 900mA p. Channel
LED flash current
2)
100mA...21A
Min flash duration
10µs
depending on LED working point
and duty cycle
Max. flash duration
59s
Max. flash latency
3)
3µs
Flash duration & delay:
smallest adjustable step
1µs
Voltage range for LED modules
approx. 2.5V to 22V
Mechanical parameter
Dimension (H x W x D)
53mm x 80mm x 93mm
Weight
220g
Connectors
1x 2 Pin plug contact (RM5.08),
1x 7 Pin plug contact (RM3.81),
4x 2 Pin inv. plug contact (RM3.81)
1x RJ45 Ethernet
Certifications
CE, RoHS
Degree of protection
IP20 (made for control cabinet)
Humidity
30% to 70%
Operating temperature
10°C to 30°C
Accessories
Top rail mounting clip and plugs (scope of de-
livery). For cable, mounts and lighting modules
please check www.mbj-imaging.com
1) LED current less than 100mA may cause LED light jitter
2) The flash energy is provided by a capacitor and requires sufficient time for
recharging. The flash energy (flash frequency * flash duration * current) is limited
to 1A. E.g.: 100 flashes/s * 100µs * 30A = 0.3A
3) The higher the current and the shorter the cycle time, the greater the latency
can be
Electrical Connections
Pin Pin Name
CTR-52 Function
Comment
1
24VDC
24V DC
Power supply input
2
GND
Ground
Power supply ground
Pin Name
Function
Comment
3
Tr.1
Trigger1 12-24V
1)
Internally opto-coupled
4
Tr.2
Trigger2 12-24V
Internally opto-coupled
5
Tr.3
Trigger3 12-24V
Internally opto-coupled
6
Tr.4
Trigger4 12-24V
Internally opto-coupled
7
Tr. GND
Trigger ground
Common Tr. ground, isolated
8
--
not used
9
--
not used
Pin Name
Wire
2)
Output to light
10
LED1+
black + blue
Channel 1
11
LED1-
3)
white + brown
Channel 1
12
LED2+
black + blue
Channel 2
13
LED2-
3)
white + brown
Channel 2
14
LED3+
black + blue
Channel 3
15
LED3-
3)
white + brown
Channel 3
16
LED4+
black + blue
Channel 4
17
LED4-
3)
white + brown
Channel 4
Port
Function
Comment
Eth
RJ45 network
Modbus over Ethernet
1) Signal high >=10V, signal low <=5V
2) For MBJ connecting cable and MBJ LED light (-x) without integrated controller
3) Do
NOT
connect LED(-)to the external ground of the power supply or the ground of
the trigger signal! This might destroy connected lights or devices
Operating Mode
Mode
CTR-52 Function
STEADY
Continuous light, LED always on
AUTO
LED output follows the trigger status
FLASH
1)
Manual set-up for flash, delay and duration via Modbus protocol
OFF
LED output is switched off
1) The CTR-52 factory setting of the operation mode is FLASH. Other operating modes
are selectable via the Modbus interface
24V DC
20 mA
Trigger LED 1
from Camera/ PLC
CTR-52
Modbus Slave
1 Tr.1
2 Tr.2
3 Tri.3
4 Tri.4
5 Tri GND
6
7
LED 1 (+)
LED 1 (-)
LED 2 (+)
LED 2 (-)
LED 3 (+)
LED 3 (-)
LED 4 (+)
LED 4 (-)
PC or PLC
Modbus Server
1k2
1k2
1k2
1k2
Trigger
GND
20 mA
20 mA
20 mA
Trigger LED 2
from Camera/ PLC
Trigger LED 3
from Camera/ PLC
Trigger LED 4
from Camera/ PLC
1k2
1k2
1k2
1k2
24V DC
24V DC
24V DC
24V DC
LED
Driver
LED
Driver
LED
Driver
LED
Driver
Triggered light with PNP sourcing
TTL triggered light with sinking output (inverted strobe signal)
Application Samples for CTR-52 Controller
Modbus Control
Hardware
The standard fieldbus provided with the CTR LED controller product line is
based on Modbus TCP. Modbus is a data communications protocol for use
with programmable logic controllers (PLCs).
Modbus Setup Information
The CTR controller is a Modbus device that allows you to access the light
settings via Ethernet. The controller communicates using a master-slave tech-
nique in which only one device (the master) can initiate transactions (called
queries). The other devices (slaves) respond by supplying the requested data
to the master, or by taking the action requested in the query.
The CTR light controller is implemented as a Modbus slave. The CTR receives
messages from the master, processes them and responds to them. The pro-
duct does not send messages by itself.
Modbus Setup Information
Modbus Type:
Slave (Server)
Modbus Format:
Modbus TCP
Output Data Mode:
Auto
Notes
‒ The default device IP address is 192.168.0.99. The address can be changed
via the command line tool provided with the MBJ software package
‒
The RESET Button on the back of the device can be used to return to the
factory default settings
‒
Please refer to the fieldbus communication protocol definition for details
Software
The CTR-52 can be programmed via different alternative methods:
‒
Direct Modbus access for which a detailed protocol definition is provided
‒ SDK library to integrate the communication into your software
‒ The easy to use MBJ software user interface based on MS Windows 10®
For further information and download of the CTR-52 software components
visit: www.mbj-imaging.com/en/products/led-controller
Flash Capacity of CTR-52
-
4V
-
12V -22V
Flash duration [µs]
Max C
urr
ent [A]