mbj CTR-52 Operating Instructions Download Page 1

Controller CTR-52

Operating Manual 

Technical Data

CTR-52

4 channel LED driver

Current controlled operation for continuous and brightness controlled LED light

Voltage controlled operation for short, precise and high-power LED flashes, precise 

flash pulses from 10µs to 100ms

Full control via Modbus TCP/IP 

MS Windows 10® based control software and SDK available

Straight flash control via the camera’s ‘exposure time’, 

the ‘strobe‘ signal or manual flash set-up

4 individual trigger I/O lines with flexible assignment to the LED channels

Passive cooling and overheat protection

 

MBJ Imaging GmbH

Jochim-Klindt-Strasse 7

+49 41 02 77 89 0 - 31

22926 Ahrensburg, Germany

[email protected]

www.mbj-imaging.com

Mechanical Integration

The CTR-52 controller is supplied with top hat rail mounting and 

plug-contacts for the LED light, control signals and input power.

Manual CTR-52 Controller: Revision 03 -  Feb 2022. INDD file Rev09.

More 2D and 3D drawings can be found online: 

www.mbj-imaging.com

Safety Notes

Before working with this unit, read the warning and application instruc-

tions carefully and completely.

      
1.  The device is designed for indoor use only. 

2.  Health

 – The device must be disconnected from the power source 

before the installation and/or maintenance can start. The device 
must not be used when a failure may cause personal injury.

3.  Electricity

 - The housing is electrically isolated from the ground of 

the power supply. Exceeding the permissible operating voltage or 
exceeding the maximum allowed switching current per channel can 
lead to the destruction of the device or to a significant shortening of 
the lifetime of the connected LED lighting module. 

4.  Mechanical integration

 – The controller is made for top hat rail 

mounting. A clip can be used to lock the unit to the top hat rail. For 
optimal heat flow a left/right distance of 10mm to next unit is rec-
ommended.

Status LED’s CTR-52

LED

Status

Meaning

LED 1

OFF

ON

Trigger low state

Trigger high state

LED 2

OFF

ON

Trigger low state

Trigger high state

LED 3

OFF

ON

Trigger low state

Trigger high state

LED 4

OFF

ON

Trigger low state

Trigger high state

Trigger Signals