MBH SP-7 Instruction, Installation, Operation And Maintenance Manual Download Page 3

4

5

© 2016 mbh pumps (gujarat) pvt. ltd.

© 2016 mbh pumps (gujarat) pvt. ltd.

(B) Reassembly Procedure :

a)  Apply a thin layer of grease to all surfaces which have to be air tight.

b)  Clean Recirculating Port in Delivery Casing.

c)  Complete the Flap -  Valve Assembly. If it is dismantled with Suction Cover and  

  wearing plates. 

d)  Mount Bearings on the Shaft so that Bearing rest against the steps provided on  

 

the Shaft. Apply grease between the two faces of the Bearings. Ball Bearings should  

  be press-fitted. If it is not possible then hammer gradually the inner race of the Ball 

 

  Bearings by putting suitable spacer on it.

e)  Insert the Shaft into the Bearing Housing from driving end.

f)  Insert the Bearing Cover, (Bearing Cap, Water Deflector, Gland and Washer for 

 

  stuffing Box Packing) on the Shaft from Non driving End Side Applicable models.

g)  Fit sub-assembly of stuffing Box Housing on Bearing Housing as applicable.

h)  Put Flat Gasket for Shaft Sleeve on the Shaft Sleeve Slot / Keyway Matches with  

  Shaft - Keyway.

i)  Fit the Bearing Cover D. E. to the Bearing Housing (as per the Model)

j)  Insert the Impeller Key into the Shaft and Shaft Sleeve and mount the Impeller on  

 

the Shaft. Lock it by Impeller Nut along with its washer. Tighten the Bearing Nut on  

  the Shaft. Check clearance between Impeller and Wearing Plate D.E. it should be  

  0.15 to 0.60mm

k)  Fit the Driving Unit (i.e. assembly of Stuffing Box Housing, Bearing Housing, Bearing 

 

  Shaft, Impeller etc.) to the delivery Casing and tighten it with the help of Nuts. The  

  clearance between impeller and wearing Plate N.D.E. should be 0.25 to 0.35mm.  

  This should be adjusted by inserting required thickness of paper packing, between 

 

  stuffing Box Housing and Delivery Casing. After fitting the Driving Unit, see that 

 

  impeller rotates freely.

l)  Insert two Stuffing Box Packings, Lantern Ring duly filled with grease and again two 

 

  Stuffing Box Packings. The joints of the Stuffing Box Packings should be 180 to 

 

  each other. Tighten the Gland by nuts.

m) Insert Coupling Key on the Shaft and mount the Pump Couplings on the Shaft and  

  tighten it by Grub Screw.

n)  Fix up grease Cups for Bearing D.E., N.D.E. and Stuffing Box.

o)  Tighten Sub-assembly of Suction Cover and Flap Valve with Delivery Casing and  

 

then tighten the Delivery Flange and Suction Flange. Tighten this to Delivery Casing  

  with its washer.

3.5 COUPLING DETAILS FOR BARE SHAFT PUMPS FOR MOTOR DRIVE LOVE 

   JOY MAKE.

Sr. 

No. Pump

Recommended 

Motor Rating

(H.P./ Kw)

Recommended Coupling Model 

Loverjoy / Equivalent)

I

MBH SP-7

1 / 0.75 2900 RPM

L - 095

II

MBH SP-9

2 / 1.50 2900 RPM

L - 095

III

MBH SP-11

3 / 2.20 2900 RPM

L - 095

IV

MBH SP-16

5 / 3.70 1450 RPM

L - 100

V

MBH SP-23

10 / 7.50 1450 RPM L - 100

4.0 GLAND PACKING CHART

Sr. 

No.

Pump

Type

No of

Packings

Size in MM 

(Height x 

Width)

Length of 

Packing /

Set (MM)

Material

I

MBH SP-7

4

8 x 8

116.5

Graphited Cotton

II

MBH SP-9

4

8 x 8

116.5

--- Do --

III

MBH SP-11

4

9 x 9

143.0

--- Do --

IV

MBH SP-16

4

8 x 8

157.0

--- Do --

V

MBH SP-23

4

8 x 8

157.0

--- Do --

4.1 BEARING DETAILS

Sr. 

No.

Pump

Type

Bearing at Driving

End (SKF / Equivalent)

Bearing at Non Driving

End (SKF / Equivalent)

I

MBH SP-7

6305

6205

II

MBH SP-9

6305

6205

III

MBH SP-11

6305

6205

IV

MBH SP-16

6306

6206

V

MBH SP-23

6306

6206

4.2 TYPE OF IMPELLER AND WEARING PLATE DETAILS

Sr. 

No.

Pump Model

Bare Shaft /

Mono Version

Type of

Impeller

Wearing Plate

Details Non

Driving End

Wearing Plate

Details Non

Driving End

I

MBH SP-7

SEMI-OPEN

No

No

II

MBH SP-9

SEMI OPEN

Yes

No

III

MBH SP-11

SEMI OPEN

Yes

No

IV

MBH SP-16

SEMI OPEN

No

No

V

MBH SP-23

OPEN

Yes

Yes

4.3 WATER FILLING CAPACITY

Sr. 

No. Pump Type

Water Filling

Capacity (Liters)

I

MBH SP-7

5.1

II

MBH SP-9

6.1

III

MBH SP-11

10.0

IV

MBH SP-16

14.0

V

MBH SP-23

37.2

Self Priming Mud Pump

Self Priming Mud Pump

Summary of Contents for SP-7

Page 1: ...SELF PRIMING MUD PUMP Instruction Installation Operation and Maintenance Manual A Mark of Quality A Mark of Quality 2016 mbh pumps gujarat pvt ltd ISO 9001 Certified Company ...

Page 2: ... done after filling clean water vi The bearings should be lubricated regularly 3 2 WARNING i When dirty water is handled by the pump of diesel engine set the same water should not be used for engine cooling In such a case radiator cooling is recommended or use air cooled diesel engine ii Use correct grade grease in grease cups Servo Gem 2 Indian Oil Make or equivalent is recommended 3 3MAINTENANCE...

Page 3: ...tates freely l Insert two Stuffing Box Packings Lantern Ring duly filled with grease and again two Stuffing Box Packings The joints of the Stuffing Box Packings should be 180 to each other Tighten the Gland by nuts m Insert Coupling Key on the Shaft and mount the Pump Couplings on the Shaft and tighten it by Grub Screw n Fix up grease Cups for Bearing D E N D E and Stuffing Box o Tighten Sub assem...

Page 4: ...ssembly leakage from pump casing 6 Replace the Shaft Sleeve Gland Packing 7 Measure the clearance and adjust by using Proper packing 8 Avoid High Suction lift and Suction Piping TROUBLE SHOOTING CHART Sr No Defects Causes Remedy 3 Pump Consumes more power 1 Speed too high 2 Head less than specified range 3 Shaft bent 4 Misalignment of the set 1 Check and correct the speed 2 Provide minimum specifi...

Page 5: ...W COVER 37 BEARING AT DRIVE END 18 BEARING COVER COUPLING SIDE 38 BEARING AT NON DRIVE END 19 BEARING COVER NON DRIVE END 8 9 2016 mbh pumps gujarat pvt ltd 2016 mbh pumps gujarat pvt ltd No DESCRIPTION No DESCRIPTION 1 PUMP BODY 20 FLANGE DELIVERY SIDE 2 IMPELLER C I 21 FLANGE SUCTION SIDE 4 PUMP SHAFT 22 KEY FOR IMPELLER 5 BEARING HOUSING 23 KEY FOR COUPLING 7 GLAND BUSH 24 25IMPELLER NUT 8 GLAN...

Page 6: ...bhpumps com exports mbhpumps com Website www mbhpumps com 10 11 WARRANTY WARRANTY 2016 mbh pumps gujarat pvt ltd 2016 mbh pumps gujarat pvt ltd No DESCRIPTION No DESCRIPTION 1 PUMP BODY 20 FLANGE DELIVERY SIDE 2 IMPELLER C I 21 FLANGE SUCTION SIDE 3 WEARING PLATE 22 KEY FOR IMPELLER 4 PUMP SHAFT 23 KEY FOR COUPLING 5 BEARING HOUSING 24 IMPELLER NUT 6 STUFFING HOUSING 25 WASHER FOR IMPELLER NUT 7 G...

Page 7: ...12 2016 ISO 9001 Certified Company This is the property of OTHER PRODUCTS OTHER PRODUCTS A Mark of Quality A Mark of Quality POLDER PUMP HORIZONTAL SPLIT CASING PUMP SUBMERSIBLE SEWAGE PUMP CENTRIFUGAL BACKPULL OUT PUMP PORTABLE SUBMERSIBLE PUMP DEWATERING PUMP SUBMERGED CENTRIFUGAL PUMP Specifications and performance are subject to change without prior notice ...

Reviews: