Pump fails to deliver

The discharge is too low

The line current is excessive

The total head is too low

The power consumption is excessive

Noisy operation of pump

CAUSE

REMEDY

The pump delivers against an 

excessively high discharge pressure.

Open the isolating valve further,

until the duty point conditions have 

been attained.

The pump and / or piping are

incompletely vented.

Vent the pump & system completely. 

Suction line or impeller clogged.

Remove deposits in the pump & piping.

• • • • •

Reverse rotation.

Change over two of the phase leads 

of the power supply cable.

• • •

Excessive wear of the pump internals.

Replace worn components by new one.

Operating Voltage too low. 

Check the supply terminals inform

the supply authorities.

• •

The motor is running on

two phase only.

Replace the defective fuse,

check the cable connection.

The rotor is out of balance.

Clean the rotor, Rebalance the

rotor dynamically.

The motor refuses to run because

there is no voltage.

Check the electrical system,

inform the supply authority.

The pump is silted up.

Clean out the inlet, Pump

components & check valve.

Defective motor or cable.

Please consult our works.

• •

Defective riser pipe. (pipe & gasket)

Replace defective lengths of riser

pipe by new ones, fit new gasket.

Abnormal (excessive) drop in the

liquid level during operation.

Please consult our works. 

• • •

The Star-Delta motor remains stuck

at the star stage during start-up.

Check the switchgear/control panel.

The isolating valve in the discharge

line is not fully open.

Open the valve fully.

Excessive amount of air or gas

in the liquid pumped.

Check the operating parameters

with reference to duty point. &

correctness of submergence.

Defective Ammeter.

Replace with new one.

The insulation resistance of the winding

is inadequate (The minimum resistance

in warm condition during operation should

be 1000 ohms / volt of operating volt.)

Please consult our works. 

• •

Defective radial bearing in the motor.

Please consult our works.

Vibration caused by improper installation. Correct the installation.

The temp. sensor for monitoring the 

temp. of winding in the control circuit

has stopped the motor because the 

winding temp is too high.

Wait for some time so that the motor 

cools down & the pumpset will start 

automatically.

6

7

Ni-Hard Submersible Pump

Ni-Hard Submersible Pump

© 2018 mbh pumps (gujarat) pvt. ltd.

© 2018 mbh pumps (gujarat) pvt. ltd.

TROUBLE SHOOTING CHART

Ni-HARD
SUBMERSIBLE
PUMP

Ni-HARD SUBMERSIBLE PUMP

The pump is warranty against defects in material and 

workmanship under normal use and service for the period of 15 

months from the date of purchase or 12 months from the date 

of commissioning, whichever is less.
The General terms and conditions for above warranty are :
1. This warranty is valid only if the pump is operated strictly as  

  per the Instructions given in the user guide attached herewith.
2. Our obligation shall be limited to rectifying; repairing or  

  replacing defective items, ex-works/service station/Authorized  

  Service Center, provided the purchaser has given immediate  

  written notice. The equipment for repairs should be returned  

  to us duly packed, on prepaid freight basis.

Model : 

 Pump Sr. No. 

Customer Name : 
Address : 
Date of Purchase / Bill No.: 
Dealers Name : 
Signature : 

 Date : 

14, G.I.D.C. Naroda Indl. Estate, Ahmedabad-382 330, India.

Phone  : 079-2282 3066 / 2282 1018

E-mail  : [email protected] / [email protected]

Website :  www.mbhpumps.com

WARRANTY

WARRANTY

Summary of Contents for Ni-HARD Series

Page 1: ...Ni HARD SUBMERSIBLE PUMP Instruction Installation Operation and Maintenance Manual A Mark of Quality A Mark of Quality 2018 mbh pumps gujarat pvt ltd ISO 9001 Certified Company ...

Page 2: ...able installation it results in increased friction losses Use the shortest possible delivery line 6 Protect cable from damage during storage transportation and operation A damaged cable may give shock or burn the motor 7 Always earth the unit before starting 8 Never hoist the pumpset up or down by the connecting cable 9 Use NRV if pipe length is more than 4 5 mtrs PRECAUTION FOR LONG STORAGE Clean...

Page 3: ...Hydrol 46 Turbol 46 u HPCL Hylube 30 Milcy 40 u IOC Servo super 10 WARNING Ensure that pump set rotates in the correct direction of rotation Always operate pumpset with the original control panel supplied by the manufacturer Never bypass any protection like Thermistor Moisture sensor Level controller In case the pump set stops due to above protection remove the pump set from sump and correct the d...

Page 4: ...th reference to duty point correctness of submergence Defective Ammeter Replace with new one The insulation resistance of the winding is inadequate The minimum resistance in warm condition during operation should be 1000 ohms volt of operating volt Please consult our works Defective radial bearing in the motor Please consult our works Vibration caused by improper installation Correct the installat...

Page 5: ...il marketing mbhpumps com exports mbhpumps com Website www mbhpumps com marg 08 2018 ISO 9001 Certified Company A Mark of Quality A Mark of Quality POLDER PUMP HORIZONTAL SPLIT CASING PUMP SUBMERSIBLE SEWAGE PUMP CENTRIFUGAL BACKPULL OUT PUMP PORTABLE SUBMERSIBLE PUMP SUBMERGED CENTRIFUGAL PUMP This is the property of ...

Reviews: