Ni-HARD SUBMERSIBLE PUMP

Instruction, Installation, Operation

and Maintenance Manual

A Mark of Quality

A Mark of Quality

© 2018 mbh pumps (gujarat) pvt. ltd.

ISO 9001

Certified Company

Summary of Contents for Ni-HARD Series

Page 1: ...Ni HARD SUBMERSIBLE PUMP Instruction Installation Operation and Maintenance Manual A Mark of Quality A Mark of Quality 2018 mbh pumps gujarat pvt ltd ISO 9001 Certified Company ...

Page 2: ...able installation it results in increased friction losses Use the shortest possible delivery line 6 Protect cable from damage during storage transportation and operation A damaged cable may give shock or burn the motor 7 Always earth the unit before starting 8 Never hoist the pumpset up or down by the connecting cable 9 Use NRV if pipe length is more than 4 5 mtrs PRECAUTION FOR LONG STORAGE Clean...

Page 3: ...Hydrol 46 Turbol 46 u HPCL Hylube 30 Milcy 40 u IOC Servo super 10 WARNING Ensure that pump set rotates in the correct direction of rotation Always operate pumpset with the original control panel supplied by the manufacturer Never bypass any protection like Thermistor Moisture sensor Level controller In case the pump set stops due to above protection remove the pump set from sump and correct the d...

Page 4: ...th reference to duty point correctness of submergence Defective Ammeter Replace with new one The insulation resistance of the winding is inadequate The minimum resistance in warm condition during operation should be 1000 ohms volt of operating volt Please consult our works Defective radial bearing in the motor Please consult our works Vibration caused by improper installation Correct the installat...

Page 5: ...il marketing mbhpumps com exports mbhpumps com Website www mbhpumps com marg 08 2018 ISO 9001 Certified Company A Mark of Quality A Mark of Quality POLDER PUMP HORIZONTAL SPLIT CASING PUMP SUBMERSIBLE SEWAGE PUMP CENTRIFUGAL BACKPULL OUT PUMP PORTABLE SUBMERSIBLE PUMP SUBMERGED CENTRIFUGAL PUMP This is the property of ...