MBA MBA20 User Manual Download Page 2

 

User Manual MBA 20 – Vers. 1.0 

MBA Instruments GmbH     Tel. +49-4106 123 888 0     [email protected] 

1.  Appropriate use 

 

The MBA20 may not be used 
without a appropriate housing. It is 
mandatory to place the MBA20 into 
a dust tight housing.  

 
WARNING: Dangers from inappropriate use  

  MBA bin level indicators are only to be installed and put 

into operation by technicians who are suitably qualified 
to carry out such work and are aware of the possible 
dangers. 

  In addition to these instructions, compliance must be 

insured with all local regulations, technical rulings and 
company-internal instructions that are valid at the place 
of use. 

  MBA bin level indicators may only be operated as it is 

described and specified in this manual. Otherwise the 
manufacturer’s warranty is no longer valid, and the unit 
could be hazardous in use. 

 

2.  Functional principle 

The electric motor rotates the shaft and the paddle slowly. 
When the bulk material surrounds the paddle, the rotation is 
blocked. The counter-torque is used to turn the motor 
mechanism against a switch which then turns the motor off. 
The switch has a second contact (potential free) which is 
used for the status indication. As soon as the bulk material 
releases the paddle again, a spring pulls the motor 
mechanism back into the working position. Thus the switch 
is released and the paddle starts rotating again

 

3.  Installation 

1.  In the bottom wall of the container, make a precision 

bore-hole that fits to the cylindrical part of the MBA 
housing (diameter matching MBA’s sealing ring). 

2.  Near this bore-hole, install a pin (or similar) matching the 

hole in the MBA 20 chassis plate, to prevent it from 
turning. 

3.  Insert the MBA 20 into the bore-hole, then fix it with a 

nut on the bulk materials side. 

4.  Provide a suitable protective covering over the 

electromechanical part. 

 
DANGER in the event of incorrect installation  

The MBA 20 is designed as a built-in unit and thus has no 
housing. To ensure safe operation, an additional housing (or 
a similar form of protection) must be installed, in order to 
protect the mechanical parts from being touched, and to 
provide safe electrical condition. Selection and installation of 
these components is the responsibility of the user. 
 
 
 
 

MBA 20 with protective cage 

1.  Make a suitably-sized circular cutout in the container 

wall. 

2.  Attach the plate of the protective cage to the inner side 

of the container. 

3.  Provide a suitable protective covering over the 

electromechanical part (on the outside).. 

 
Dimension  MBA 20 

 

 

 

 

 

4.  Electrical connection 

MBA bin level indicators are provided with 4 different types 
of electronics: AC or the DC electronic. The accompanying 
papers will tell you which MBA model you have. The circuit 
diagrams in this manual show the switching status when the 
paddle is rotating. MBA’s motor mechanism requires around 
3 seconds to indicate stopping or restarting of the paddle 
(switching delay due to the mechanical sequence). For units 
with fast-rotating paddle (option), the delay is around 0.6 
seconds. There can be some more timing delays due to 

-  

the characteristics of the bulk material 

- torsion effects (e.g. cable shaft, rubber paddle) 
 

 