This application illustrates the method of linking 2 Mono amplifiers to a single subwoofer. 

1.

 Connect the full range RCA outputs from the headunit to the MLX-100 inputs.

2.

 Connect the RCA’s from the MLX-100 (A+ and A-) BRIDGING OUTPUTS to the amplifier INPUTS as shown.

3. 

The amplifier settings need to be adjusted as follows:

   - The LOW PASS FILTER should be turned towards the highest frequency. (EXAMPLE: LOW PASS range = 35Hz to 250Hz, adjust to 250Hz)
   - The SUBSONIC FILTER should be turned towards the lowest frequency. (EXAMPLE: SUBSONIC range = 15Hz to 35Hz, adjust to 35Hz)
   - The PHASE should be at 0.
   - The BASS BOOST/BASS EQ should be at 0dB.
   - The LEVEL(gain) control should be turned to the 12 o’clock position.

4. 

 The INPUT LEVEL control on the MLX-100 should be set to match the output signal voltage from your headunit.

5. 

The MLX-100 LOW PASS FILTER, SUBSONIC FILTER and PARAMETRIC BASS EQ settings should be adjusted for desired listening.

6. 

The MODE switch should be in the MASTER position.

7. 

The OUTPUT LEVEL should be at 1 Volt.

At this point you are ready to balance the speaker output from your amplifiers. For this procedure you will need a Digital Voltmeter.
- Switch the MLX-100 TEST TONE switch to the ON position.
- Adjust your Voltmeter so that it is measuring Volts AC.
- Connect the positive Voltmeter lead to the (+)POSITIVE SPEAKER TERMINAL on amplifier #1. 
- Connect the negative Voltmeter lead to the (-)NEGATIVE SPEAKER TERMINAL on amplifier #1. 
- Turn the audio system on, turn the volume all the way down, and ensure that there is no audio CD in your CD player.
- Start off with the input LEVEL(gain) settings of the 2 amplifiers at top dead center, or the 12 o’clock positions.
- While measuring the Voltage AC on amplifier #1, continue adjusting level control until you measure anywhere from 4-6 Volts. At that point, write down the 
voltage on a piece of paper. 
-Connect the voltmeter to the speaker terminals of amplifier #2.
- Now adjust the input gain control of amplifier #2 for the same voltmeter reading as you had noted down .

8

Once the amplifiers have matching output voltages, you should turn the 65Hz TEST TONE to the OFF position.

9.

 Connect the speaker  + terminal to the POSITIVE SPEAKER TERMINAL of  amplifier #1.

    Connect the speaker  -  terminal to the POSITIVE SPEAKER TERMINAL of  amplifier #2.
    Connect a wire link between the NEGATIVE SPEAKER TERMINALS of the two amplifiers.

10. 

Use the OUTPUT LEVEL  adjustment to obtain the desired audio level.

11.

 The steps outlined in #8 may have to be repeated if you cannot get full power out of the amplifiers, in which case, start off with their input gain controls set for higher gain.

 

Note: Up to 10 amplifiers can be connected in this manner,

by also using MLX-100 outputs  B thru E.

Mono bridging 2 standard mono amplifiers with no Master/Slave feature to a single subwoofer

MAXX-LINK MLX-100 BRIDGING MODULE APPLICATIONS

4

Summary of Contents for MAXX-LINK MLX-100

Page 1: ......

Page 2: ...ding your system and allowing for linking of non linkable mono block amplifiers FeatureDescriptions 1 EndPanel FrontMountControls andRemoteModuleDrawings 2 Application Diagram 3 Linking2MLX 100susingM...

Page 3: ...ition when it is being controlled by another MLX 100 LOW PASS FILTER The Low Pass Filter is fully adjustable from 35Hz to 250Hz at 24dB per Octave SYSTEM DIAGNOSTICS The MLX 100 has built in monitorin...

Page 4: ...E OFF MASTER RED CLIP GREEN 9V TEST TONE 65Hz 35Hz 250Hz 1V 9V 5V 7V 3V 15Hz 35Hz BR 1 Remote Module NORMAL OPERATION Allows use of variable LEVEL control BYPASS OPERATION Ouput is fixed at 0dB By swi...

Page 5: ...OUTPUTS A B C D E GND REM 12V SLAVE LEVEL BYPASS NORMAL RED CLIP GREEN 9V 20dB 0dB 6dB Linking 2 MLX 100s using Master Slave operations This application illustrates the method of linking 2 MLX 100 s...

Page 6: ...ER TERMINAL on amplifier 1 Connect the negative Voltmeter lead to the NEGATIVE SPEAKER TERMINALon amplifier 1 Turn the audio system on turn the volume all the way down and ensure that there is no audi...

Page 7: ...z 35Hz 250Hz 1V 9V 5V 7V 3V 15Hz 35Hz INPUT INPUT LEFT RIGHT FULL RANGE BR 1 REMOTE CONTROL MASTER OUT SLAVE IN BRIDGING OUTPUTS A B C D E GND REM 12V Mono Block Amplifiers Speaker Terminals Speaker T...

Page 8: ...EAKER TERMINAL on amplifier 1 Connect the negative Voltmeter lead to the NEGATIVE SPEAKER TERMINALon amplifier 1 Turn the audio system on turn the volume all the way down and ensure that there is no a...

Page 9: ...z INPUT INPUT LEFT RIGHT FULL RANGE BR 1 REMOTE CONTROL MASTER OUT SLAVE IN BRIDGING OUTPUTS A B C D E GND REM 12V INPUT L R INPUT L R INPUT L R INPUT L R Mono Block Amplifiers MAXX LINK MLX 100 BRIDG...

Page 10: ...2 Another major problem that can cause excessive hiss is a noisy head unit unplug the MLX 100 input RCA cables and if the hiss level reduces thesourceunitisatfault Electricalinterference The inside o...

Page 11: ...g returned Valid purchase receipts will contain the name and address of the authorized reseller Any damage to the product as a result of misuse abuse accident incorr ect wiring improper installation a...

Page 12: ......

Reviews: