Navigating the Menu System

Select Main Menu

 or 

Move up and down through the sub-menus:

1. Timed 

Measure

This function allows users to take measure-

ments over a de

fi

 ned amount of time.  This 

is useful for detecting small amounts of con-

tamination.

2. Set 

Units

Users can select either 

μ

R/hr, mR/hr,

μ

Sv/hr, CPS or CPM measurement units.     

3. Settings 

This sub-menu allows the user to custom-

ize the behavior of the PRM-8000.  Settings 

include those associated with the beeper, 

LED, dose-rate alarm, time/date, power set-

tings as well as the control over the averag-

ing performed at low dose rates.

4. Utilities

This sub-menu includes functions to reset 

the measurement counters (Average, Mini-

mum, Maximum, Total and Elapsed Time), 

perform a hardware reset, power down the 

device, load the factory calibration values, 

display the voltage of the battery and per-

form the calibration procedure.

     

5. Ext 

Audio/Data

This sub-menu is used to control the 

behavior of the audio/data jack.  The jack 

can output audio at three selectable volume 

levels, provide a pulse output compatible 

with third party software or output a serial 

data stream (optional cable required) on 

the minute for data collection using a PC.

6. Data 

Logging

This sub-menu provides functions to control 

data logging to the internal logging memory 

in the PRM-8000.

7. Language

This allows the user to set the language to 

either English or Japanese 

Select the desired sub-menu.  Repeat the pro-
cess for navigating through the sub-menus

Return to previous menu

Summary of Contents for PRM-8000

Page 1: ...PRM 8000 Nuclear Radiation Monitor Quick Start Guide...

Page 2: ...lit LCD B Radioactive Event LED Indicator C Back Key D External Audio and Data Jack E External DC Power Input Jack F Up Key G Down Key H Sound Port I Select Power On Key J Geiger M ller Tube Window Po...

Page 3: ...will continue to monitor and measure radiation including current average maximum minimum and total count values Pressing any key will wake up the display and op erations will continue normally until t...

Page 4: ...reset the measurement counters Average Mini mum Maximum Total and Elapsed Time perform a hardware reset power down the device load the factory calibration values display the voltage of the battery and...

Page 5: ...ettings Beeper Medium Sets beeper volume control OFF Low Medium High LED ON Sets LED indicator on or off ON OFF Alarm OFF Sets dose rate alarm on or off ON OFF mR hr Alarm uSv hr Alarm Set Time Date S...

Page 6: ...e performed by a certi fied lab with a certified Cs137 source Ext Audio Data Off Provisions the external audio and data jack for use with either headphones or the optional USB interface cable The Puls...

Page 7: ...void any contact with areas underneath or past the LCD towards the front of the device 3 Remove the top part of the case and gently place it on it s face being careful not to over extend the ribbon ca...

Page 8: ...DN PRM8000QS EN Mazur Instruments 200 South Wilcox Street 448 Castle Rock CO 80104 USA www MazurInstruments com...

Reviews: