CHARGING SYSTEM [13B-MSP]
01-17–1
01-17
01-17
CHARGING SYSTEM [13B-MSP]
CHARGING SYSTEM OUTLINE
[13B-MSP] . . . . . . . . . . . . . . . . . . . . . . . 01-17–1
Features
. . . . . . . . . . . . . . . . . . . . . . . . 01-17–1
GENERATOR CONSTRUCTION
[13B-MSP] . . . . . . . . . . . . . . . . . . . . . . . 01-17–1
End of Toc
NG: CHARGING SYSTEM
CHARGING SYSTEM OUTLINE [13B-MSP]
id0117f2102100
Features
End Of Sie
NG: GENERATOR
GENERATOR CONSTRUCTION [13B-MSP]
id0117f2102300
!
With the elimination of the voltage regulator, generator control is carried out by the PCM. Excitation current in
the field coil is increased or decreased by the duty signal from the PCM sent to the power transistor built into
the generator.
Improved generator output
!
Generator changed
PULLEY
FRONT COVER
FRONT BEARING
ROTOR
REAR BEARING
STATOR COIL
REGULATOR
COMPONENT
(BUILT-IN POWER
TRANSISTOR)
RECTIFIER
REAR COVER
TERMINAL B
ar8uun00000358