background image

Close the terminal cover (negative side).

Remove the nut shown in the figure and disconnect the positive terminal.

Close the terminal cover using the following procedure.

Open the terminal cover (negative side).

Close the terminal cover (positive side).

Close the terminal cover (negative side).

Apply an insulating tape as shown below to prevent short circuit.

8

Summary of Contents for 2007 Mazdaspeed 3

Page 1: ...ration Customer Service Div Recycle Promotion Gr Issued Ver 1 1 2021 03 Information in this manual is subject to change without notice For Dismantler M Hybrid Battery Disposal Manual Target Model MAZD...

Page 2: ...ts 1 Intoroduction 2 Overview for M Hybrid Battery 3 Hndling for M Hybrid Battery 4 Recommendaiton for safe collection of M Hybrid Battery 5 Removed M Hybrid Battery 6 Storage for removed M Hybrid Bat...

Page 3: ...ration M Hybrid Battery is installed under the floor outside the cabin in front of the vehicle The battery has a ground plate to separate it from the vehicle ground Removing the ground plate cuts off...

Page 4: ...u start remove the following metal products Short circuiting of the battery related components may cause sparks fires and damage to components Metal scale mechanical pencil etc Accessories necklaces r...

Page 5: ...shock etc Do not leave discard divert modify disassemble resell transfer M Hybrid Battery Touching of the battery that has been Improperly left or discarded or diverting remodeling or disassembling i...

Page 6: ...battery Otherwise it could be damaged Terminal cover 1 Switch the ignition OFF 2 Disconnect the negative battery terminal and wait for 1 min or more 3 Lift up the vehicle 4 Disconnect the ground plat...

Page 7: ...and remove the ground plate Installing a ground plate with a failed battery stuck internal relay can cause a short circuit Remove and store the ground plate from the battery Open the terminal cover p...

Page 8: ...and disconnect the positive terminal Close the terminal cover using the following procedure Open the terminal cover negative side Close the terminal cover positive side Close the terminal cover negati...

Page 9: ...ar Tunnel member 6 Disconnect the connector 7 Remove in the reverse order of removal M Hybrid Battery component Bracket No 1 Short cord Bracket No 2 M Hybrid Battery When removing be careful attention...

Page 10: ...ng the surrounding area of the fire pouring large amounts of water is an effective measure to prevent the fire from spreading Fire extinguishing Extinguish the fire from upwind and wear respiratory pr...