This manual contains important information about the operation and safe 
use of this product.

READ AND FOLLOW ALL INSTRUCTIONS. IMPORTANT SAFETY 
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, 
OR INJURY TO PERSONS.

WARNING

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, unless they have been given supervision or instruction 
concerning the use of the appliance by a person responsible for their 
safety. Children should be supervised to ensure they do not play with the 
appliance.

WARNING

Do not open the Electronic Control Unit. There is no user-serviceable part 
in the control box. Repairs are only to be made by an Eco Swim qualified 
technician. If the supply cord is damaged, it shall only be replaced by the 
manufacturer or its service agent or a similarly qualified person to avoid a 
hazard.

WARNING

Do not operate the electrolytic cell without proper flow or water 
circulation as this may cause damage to the unit.

CAUTION

This unit is not intended for use with temporary or fold-able/storable 
pools. All pipe-work associated with this system is intended to be fixed 
and should remain intact following installation by qualified personnel.

Important Safety Information

Congratulations on your choice of an Eco Swim pool sanitation system 
for your swimming pool. Eco Swim is designed for easy and simplistic 
operation and maintenance.

Please take the time to read these instructions thoroughly before 
attempting to operate your unit. Should you require additional information 
or further assistance, do not hesitate to contact your local Eco Swim 
representative or visit our website 

www.maytronics.com.au

.

Eco Swim Exceptional Pool Sanitation

Summary of Contents for ECO SWIM 100

Page 1: ...ECO SWIM 100 200 300 USER MANUAL v 1 ...

Page 2: ...f the supply cord is damaged it shall only be replaced by the manufacturer or its service agent or a similarly qualified person to avoid a hazard WARNING Do not operate the electrolytic cell without proper flow or water circulation as this may cause damage to the unit CAUTION This unit is not intended for use with temporary or fold able storable pools All pipe work associated with this system is i...

Page 3: ...g these products These products are designed and tested to conform to AS NZS 3136 AS NZS 3100 To comply with this standard the chlorinator must not be installed in the pool zone Trademarks Throughout this document trademark names may have been used Rather than placing a trademark symbol in every occurrence of a trademark name we state that we are using the names only in an editorial fashion and to...

Page 4: ...del only 3 Fuse 10 pH Drive Socket 12V plug 4 Sanitation Switch 11 Positive Cell Lead Red 5 Master Switch 12 Negative Cell Lead Black 6a Chlorine Cell Output Control 0 99 13 Gas Sensor Connector White 6b Push menu for e Series Dosage menu d0 d9 Pr Prime 14 Timer 7 Pump Outlet Socket 14 4 5 3 7 8 9 11 12 13 1 2 6a ES100 ES200 ES300 units ES100 200 300 units can be upgraded with Ozone and pH control...

Page 5: ... possible damage from severe weather conditions Step 2 Plumb chlorine cell onto return pipe after filter ensuring there is a gas trap Please ensure correctly rated PVC pressure glue is used Step 3 Connect the chlorine cell cable to the three colour coded terminals located on chlorine cell Terminals need to be slightly crimped for snug fit Step 4 Ensure pool is correctly balanced refer to page 17 E...

Page 6: ...lar heating system be installed the housing must be plumbed after the solar diverters and after the water exits the solar system and re joins the main stream pool return line Ensure there is a gas trap by always installing the chlorinator cell at a higher level than the filter see below CHLORINATOR CELL MEDIA FILTER CHLORINATOR CELL CARTRIDGE FILTER CHLORINATOR CELL CARTRIDGE FILTER SAFE SAFE DANG...

Page 7: ...ol water To assist in the rapid dissolving and mixing sweep or brush the solids until they are fully dissolved Note Undissolved salt may result in staining of your pool s interior walls Achieving the correct salt mineral levels New Pools Existing Pools For best results the salt concentration in the pool water is required to be within an average range of approximately 3 500 to 4 500ppm Check salt m...

Page 8: ...er see setting the timer to run for the recommended times 4 6 hours for winter 8 10 hours for summer switch the system to auto and the unit will now be controlled by the timer To set current time rotate minute hand clockwise until arrow head aligns with correct time Note This will need to be reset whenever the power is disconnected from the unit and for daylight saving time changes Note Only rotat...

Page 9: ...ppm Cyanuric Acid CA 30 50 ppm Phosphates 0 300 ppm TDS 3500 4500 ppm Water Chemistry Balancing Information Electrode Cell Cleaning Although you have a reverse cycle automatic cell cleaning system it is recommended from time to time that the cell be checked for any accumulation of calcium or other deposits that may have built up We recommend cleaning the cell once or twice a year subject to your p...

Page 10: ...ranty 1 YEAR IN FIELD on the conrol box 5 year pro rata warranty of chlorinator cell 2 Year Full year 3 4 5 Pro rata Activate your Eco Swim warranty by registering at maytronics com au support registration Warranty Information 5 Y ear Cell Warran t y 2 Year Full Warran t y 5 Year Warranty ...

Page 11: ...ashing Too much salt has been added to the pool Take a sample to your local pool shop to confirm salt levels and remove and replace water as required No display No mains power Unit is turned off Ensure there is mains power available Check fuse condition and call technician if blown Ensure manual mode and sanitation are switched on Low No Chlorine Insufficient run times Incorrect cell production se...

Page 12: ...maytronics com au ...