background image

14

Dolphin Bio Suction

  

|

  

User Instructions Manual

7.3.  Manual direction control mode

Manual Direction Control Mode

1. Press the On/off button once. 

The remote control will start in 
manual direction control mode.

2. Use the direction control 

arrows (see right) to control the 
movement of the robot around 
the pool.

Exiting Manual Direction Control Mode 

1. To exit the manual direction 

control mode, press the Manual/
automatic select button once 
only.

2. The digital screen will light up 

and three rows of function icons 
will be displayed in default 
mode.

3. To change the parameters press 

the up or down arrows.
To select the parameter settings 
use the right or left arrows.

4. When you reach the required 

function press the Set/OK 
button.

Bio_English_8151191.indd   14

1/12/12   6:27 PM

Dolphin Bio Suction

  

|

  

User Instructions Manual

7

3.  Place the robot on the edge of the pool and let the water drain out.
4.  Clean the filter cartridges.
5.  Rinse all brushes with clean water after each cleaning cycle.
6.  Place the robot on its Caddy in a shady area.

5.6.  Cleaning the filter cartridges

CAUTION

 Note: Do not let the filter cartridges dry out before cleaning.

•  Unplug the power supply before any servicing activity, including cleaning the filter cartridges.

1.  Open the filter covers and remove the cartridges from both sides of the robot.
2.  Open the clips and remove the filters.

1

2

Bio_English_8151191.indd   7

1/12/12   6:27 PM

Summary of Contents for Dolphin Bio Suction

Page 1: ...www maytronics com by Dolphin Bio Suction Bio_cover_English_8151191 indd 4 1 12 12 5 03 PM by 8151191 User Manual Instructions Dolphin Bio Suction Bio_cover_English_8151191 indd 1 1 12 12 5 03 PM...

Page 2: ......

Page 3: ...5 Removing the robot from the pool 5 6 Cleaning the lter cartridges 7 5 7 Dismantling and cleaning the impeller 9 5 8 Storage instructions 9 6 USING THE EXTERNAL SUCTION PIPE 9 7 USING THE REMOTE CON...

Page 4: ...hours according to the pool s speci c cleaning requirements 2 SPECIFICATIONS Motor protection IP 68 Minimum pool depth 0 80m 2 6ft Maximum pool depth 5m 16 4ft Water temperature 6 34 C 43 93 F 3 WARN...

Page 5: ...3 4 POOL CLEANER PARTS Dolphin Bio Suction Caddy Weekly timer Power Supply Internal suction adaptor Swivel to pipe connector Suction inlet plug Cable to pipe clip connector Remote Control Unit Pipe op...

Page 6: ...h it out completely so that it has no kinks Adjusting the handle angle The handle angle can be adjusted to determine the speed at which the robot advances along the water line To adjust the handle ang...

Page 7: ...he robot is disengaging from wall at water line If the robot climbs too high consult your Dolphin distributor Remote control unit is not working Check if the batteries need to be replaced Motor is not...

Page 8: ...ECT button you can choose a pool cleaning schedule for the coming week Important The robot will always begin to work upon set up LED 1 The robot will automatically work every day for a full cycle 7 ti...

Page 9: ...arrows To select the parameter settings use the right or left arrows 4 When you reach the required function press the Set OK button Bio_English_8151191 indd 14 1 12 12 6 27 PM Dolphin Bio Suction User...

Page 10: ...cycle Fast 2 hour cycle Ef cient 3 hour cycle for everyday use default setting Heavy duty 4 hour cycle Delay time indicator This determines when the pool cleaner starts to work Delaying allows the dir...

Page 11: ...hin Bio Suction User Instructions Manual 9 5 7 Dismantling and cleaning the impeller Unplug the power supply before cleaning Dismantle the impeller cover and clean around the impeller housing then rea...

Page 12: ...ted connect clip connectors along the entire length of the pipe CAUTION Note 1 To avoid the pipe twisting use only the minimum pipe length necessary for the robot to reach all corners of the pool 2 Im...