1. General Information

1.1 Introduction

The "Multicom Stationary 2.4G" is designed by using the most advanced 

Multiplex communication technology. 

It serves user-friendly features and extremely convenient to operate 

including a crystal clear sound quality and also long distance 

communication coverage.

It gives the operation as a central broad cast station to the unlimited 

number of listeners who carry the MTT-R Receiver devices with them 

and also provides a communication in full duplex with up to two other 

users who carry the MTT-T Multicom devices.

It is recommendable you read the user's manual thoroughly to enjoy 

its maximized performance  and features this station has to offer.

1.2 Main Features

* Audio publishing to the unlimited number of people who carry the 
   MTT-R Receiver
* Multiplex communication with up to two other users who carry the 
   MTT-T Multicom devices
* Long distance communication coverage over 400m typically
* Crystal clear sound quality
* 39 different Group selection
* Audio output HI/Low selection
* Audio volume control with 9 steps
* Side tone On/Off selection
* Direct microphone sensitivity control with 5 steps
* Convenient dual external power supply source either USB plug for the 
   purpose of its portable using by connection Mobile phone 
   Power bank into it or DC 5.0V adapter via AC input

Summary of Contents for MS-1124G

Page 1: ...MULTICOM STATIONARY 2 4G USER S MANUAL ...

Page 2: ...It is recommendable you read the user s manual thoroughly to enjoy its maximized performance and features this station has to offer 1 2 Main Features Audio publishing to the unlimited number of people who carry the MTT R Receiver Multiplex communication with up to two other users who carry the MTT T Multicom devices Long distance communication coverage over 400m typically Crystal clear sound quali...

Page 3: ...ity level and Audio Output Loud Control to be Up the level in the selected mode Control to be Down the level in the selected mode 3 5mm External Headset Boom Microphone Jack EHR 01 XLR Headset Jack Long diversity Antenna Jack USB Jack compatible with Power Bank for mobile phones 55 Jack Audio Output XLR Jack Audio Output UP Button Down Button Mode Button 55 Jack XLR 3PINs Antenna Jack USB XLR 4PIN...

Page 4: ... device power on It is available to adjust the volume level 0 9 from low to high Note The default volume level is 3 and the volume level returns to 3 all the times whenever you power switch turned off and on Show the selected Group Number 00 Show the selected Group Number 01 3 3 Group selection Press and hold the Mode button longer than 3 seconds after turn the device power on The GRP symbol on th...

Page 5: ...onger than 5 seconds to fix it 3 5 Audio Output mode High Low It serves you to choose higher audio output or lower beside of Volume Up Down The higher audio output is effective when you listen to the device at the heavy noise place Press and hold the Mode button longer than 3 seconds after turn the device power on The GRP is blinking on the LCD Press the Mode button 6 times instantly Select either...

Page 6: ...y Select the microphone sensitivity level 1 5 as per you desire by press or button and then release all the buttons longer than 5 seconds to fix it 3 7 Portable using It is available to use the Stationary as a portable device rather than the fixed station Please connect the Power bank for Mobile phone into the USB port of Stationary After that place the stationary wherever you prefer Note 1 Its de...

Page 7: ...vity 95dBm Voice Latency 35ms Num of Frequency Channel 145CH Operation Hopping 16CH Channel Spacing 0 5MHz Data Rate 0 5Mbps Freq Bandwidth 2MHz Power Supply Output Voltage DC 5 0V Antenna Type Dipole Antenna Reverse SMA type Antenna Gain 5 0dBi Power Consumption Avg 180mA Distance Range LOS 200M Frequency response 50Hz 4KHz The antenna is not standard type that is special reverse type So the usin...

Page 8: ...T R Listening device regardless its ID number Notice It is required to tune the same group number between Stationary and two other MTT T devices Also the two other MTT T devices should have each different ID per device except the ID 00 of Stationary owned 100 400m distance Stationary MTT T 1 Unlimited Listeners with MTT R Speaking only or Speaking and Listening 100 400m distance MTT T 2 ...

Page 9: ...and Stationary It is available to repeat the communication in one Stationary to the other Stationary by cable connection between two stationeries Please connect to two XLR 3 port of Stationeries by using XLR Repeater only cable 5 3 Full duplex communication and general publishing Unlimited number of Listeners with MTT R Full Duplex communications between Stationary MTT T1 and MTT T2 Listening all ...

Page 10: ...ncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is con nected Consult the dealer or an experienced radio TV technician for help Caution Modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Compliance Information T...

Page 11: ... product statements This product is CE marked according to the provisions of the R TTE Directive 1999 5 EC Hereby Maytel Co Ltd declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC For further information please contact http www maytel com Maytel Co Ltd 417 Doosan Venture Digm 126 1 Pyeongchon dong Dongan gu Anyang si Gyeo...

Page 12: ...represent local contacts for this product CORPORATE HEADQUARTERS MAYTEL CO LTD 417 Doosan Venture Digm 126 1 Pyeongchon dong Dongan gu Anyang si Gyeonggi do Republic of Korea Tel 82 31 478 5508 Fax 82 31 440 9331 Web http www maytel com This device complies with Industry Canada license exempt RSS standard s Operation is Subject to the following two condition 1 this device may not cause interferenc...

Page 13: ...epublic of Korea declare under our sole responsibility that the product s Multicom Stationary 2 4G MTT Stationary T 1 MS 11 2 4G to which this declaration relate s is in conformance with the following standards EN 301 489 1 V1 9 2 2011 EN 301 489 17 V2 2 1 2012 EN 60950 1 2006 A2 2013 EN 300 328 V1 9 1 2015 following the provisions of the 1999 5 EC Directives ...

Reviews: